Technical data

TROUBLESHOOTING22
Smoke escaping
Damp wood
Chimney not drawing properly
Chimney is not properly dimensioned for the stove
Check if the smoke gas pipe/chimney are blocked
Is the chimney the right height for its surroundings?
Vacuum in room
The door is opened before the embers have burned down
sufficiently
Wood burning too quickly
The air valves are set incorrectly
The smoke deflector plates is incorrectly mounted or missing
Inferior firewood (waste wood, pallets etc.)
Chimney too large
Soot build-up on glass
Incorrect secondary airflow setting
Excessive primary air
Damp wood
Wood pieces too large on lighting
Inferior firewood (waste wood, pallets etc.)
Chimney not drawing sufficiently
Vacuum in room
Excessive soot build-up in chimney
Poor burning (more air required)
Damp wood
The surface of the stove is turning grey
Overheating (see instructions for heating)
Poor heating performance of stove
Damp wood
Not enough wood
Inferior wood quality with low fuel value
Smoke deflector plates are not fitted correctly
Odour coming from stove
The lacquer on the stove hardens when you use the stove for the
first time; this can cause an odour. Open a window or a door for
ventilation, and make sure the stove is heated up sufficiently to
avoid odours later.
When heating up and cooling down, the stove may make some
clicking noises. These are due to the huge temperature dif-
ferences to which the material is exposed and do not indicate
any product defects.
Warranty
All wood-fired Scan products are made of high-quality materials and
subject to strict quality controls before leaving the factory. We give a
warranty of 5 years on manufacturing errors or defects.
You must quote your stove‘s product registration number when you
contact us or your authorised Scan dealer with a warranty claim.
The warranty covers all parts which in the opinion of Scan A/S require
repair or replacement due to manufacturing or construction error
The warranty applies to the original purchaser of the product only,
and is not transferable (except on prior sale).
The warranty covers only damage caused by manufacturing or con-
struction errors.
The following parts are not covered by the war-
ranty
Wear and tear parts, such as the combustion chamber liners,
smoke deflector plates, shaker grate, glass, tiles, and seals
(except for defects which were present on delivery).
Defects caused by external chemical and physical influences
during transportation, storage and assembly, or at a later time.
Soot build-up caused by poor chimney draught, damp wood, or
improper use.
Costs of additional heating in connection with a repair.
Transport costs.
Costs for setting up, removing the wood stove.
This warranty is void
In case of incorrect installation (the installer is responsible for
observing and complying with legal requirements and local
bylaws, along with this Assembly- and Instructionsmanual for
the wood-burning stove and accessories).
In case of improper use, and/or use of prohibited fuels, non-ori-
ginal spares (see this Assembly- and instructions manual).
If the product registration number of the stove has been remo-
ved or damaged.
In case of repairs that do not comply with our instructions or
instructions by an authorised Scan dealer.
In case of any manipulation of the original state of this Scan
product or its accessories.
This warranty is only valid in the country to which this Scan
product was originally supplied.
Always use original replacement parts, or parts recommended by the
manufacturer.