Technical data
ASSEMBLY
10
Additional accessories
• Large shaped floor plate in glass or steel.
• Small shaped floor plate in steel
• Soap stone top for rear outlet
• Soap stone top for top outlet
• Soap stone top for stove with soap stone sides
• Soap stone top with hole for stove with soap stone sides
• Glass top plate for rear outlet
• Glass top plate for top outlet
• Storage door
• High top (Scan 58-7 and Scan 58-8)
• Wall mounting kit for Scan 58 with high top
Transport brackets
For Scan 58 with pedestal and see-through base / Scan 58 wall model,
remove the transport brackets as shown below.
Service box
The service box contains the following:
• Fitting for connecting piece
• Seal
• Safety fitting
• Plastic plugs for transport safety hole at the bottom of
the stove (not used for this Scan model)
• Various tools
• Glove
• Fire starters for first lighting
Scan 58-9 & Scan 58-10
Scan 58-9 + Scan 58-1
0
Freestanding room heater
f
ired by solid
f
ue
l
Stan
d
ar
d:
Fue
l
t
y
pe
:
Operation t
y
pe
:
The appliance can be operated in a shared flue.
y
C
ountr
y
E
N 1
3
240 EC no. 90
358
61
7
Wood
Int
e
rmitt
e
n
t
E
U
R
Norway
y
C
l
ass
ific
a
ti
on
Int
e
rm
i
tt
e
nt
K
lasse
2
C
erti
f
icate/Standar
d
EN
1
3
240
SINTEF 110-029
8
A
pp
rove
d
by
pp y
RWE P
o
w
e
r A
G
S
INTEF - NBL
Dust at 13
%
O2: 44 mg/Nm
³
Flue gas temperature: 350
°C
Nomina
l
h
eat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
Minim
u
m
d
i
s
t
a
nc
e
t
o
c
o
m
bus
ti
ble
m
a
t
e
ri
als:
Si
d
e:
35
0 mm - Bac
k
: 2
5
0 mm - Front: 1000 m
m
CO emission at 13% O2
:
Fo
ll
ow assem
bl
y- an
d
instructions manua
l.
Use only recommended
f
uels
.
Monta
g
e- un
d
Be
d
ienun
g
san
l
eitun
g
b
eac
h
ten.
V
erwenden Sie nur empfohlene Brennstoffe
.
1000 06-2010
Scan A/S DK
549
2 V
i
ssen
bj
er
g
0,11
%
1338 mg/Nm
³
S
c
h
w
e
i
z
G
erman
y
y
y
LRV 1
1
BStV 1
VKF N 18900
FSPS-Wa 176
9
-EN
RWE P
o
w
e
r A
G
RWE Power A
G
Scan 58-9 & Scan 58-10 with high top
Scan 58-9 + Scan 58-10 wit
h
h
i
gh
to
p
Freestanding room heater fired by solid fue
l
Stan
d
ar
d
:
Fue
l
type
:
Operat
i
on t
y
pe
:
The appliance can be operated in a shared flue.
y
C
ountr
y
E
N 1
3
240 EC no. 90
358
62
0
W
oo
d
Int
e
rm
i
tt
e
n
t
E
U
R
Norway
y
A
us
tri
a
C
l
ass
ific
a
ti
on
Int
e
rm
i
tt
e
nt
K
lasse
2
C
erti
f
icate/Standar
d
EN
13240
SINTEF 110-02
98
1
5
a B-V
G
A
pp
rove
d
by
pp y
RWE Power A
G
S
INTEF - NBL
RWE Power A
G
Dust at 13
%
O2: 44 mg/Nm³
Flue gas temperature: 300
°
C
Nomina
l
h
eat output: 5,5
kW
E
ff
iciency: 80
%
A
n
g
aben für Österreic
h
Wärme
l
eistungs
b
ereic
h
: 3,0 - 6,7
kW
Brennstoffwärmeleistung: 8,4 k
W
Zulässige Brennstoffe: Scheithol
z
Prüfbericht:
F
SPS-Wa 176
9
-A
Scan A/S DK 5492 Vissenbjerg
Minim
u
m
d
i
s
t
a
nc
e
t
o
c
o
m
bus
ti
ble
m
a
t
e
ri
als:
Si
d
e:
35
0 mm - Bac
k
: 2
5
0 mm - Front: 1000 m
m
CO emission at 1
3
% O2
:
Fo
ll
ow assem
bly
- an
d
instructions manua
l.
Use only recommended fuels
.
Montage- un
d
Be
d
ienungsan
l
eitung
b
eac
h
ten.
V
erwenden Sie nur emp
f
ohlene Brennsto
ff
e
.
1000 06-2010
Scan A/S DK
549
2 V
i
ssen
bj
er
g
0,11
%
1338 mg/Nm
³
S
c
h
w
e
i
z
G
erman
y
y
y
LRV 1
1
BStV 1
VKF N 18900
FSPS-Wa 176
9
-EN
RWE P
o
w
e
r A
G
RWE P
o
w
e
r A
G