Technical data

ASSEMBLY
10
Additional accessories
Large shaped floor plate in glass or steel.
Small shaped floor plate in steel
Soap stone top for rear outlet
Soap stone top for top outlet
Soap stone top for stove with soap stone sides
Soap stone top with hole for stove with soap stone sides
Glass top plate for rear outlet
Glass top plate for top outlet
Storage door
High top (Scan 58-7 and Scan 58-8)
Wall mounting kit for Scan 58 with high top
Transport brackets
For Scan 58 with pedestal and see-through base / Scan 58 wall model,
remove the transport brackets as shown below.
Service box
The service box contains the following:
Fitting for connecting piece
Seal
Safety fitting
Plastic plugs for transport safety hole at the bottom of
the stove (not used for this Scan model)
Various tools
Glove
Fire starters for first lighting
Scan 58-9 & Scan 58-10
Scan 58-9 + Scan 58-1
0
Freestanding room heater
f
ired by solid
f
ue
l
Stan
d
ar
d:
Fue
l
t
y
pe
:
Operation t
y
pe
:
The appliance can be operated in a shared flue.
y
C
ountr
y
E
N 1
3
240 EC no. 90
358
61
7
Wood
Int
e
rmitt
e
n
t
E
U
R
Norway
y
C
l
ass
ific
a
ti
on
Int
e
rm
i
tt
e
nt
K
lasse
2
C
erti
f
icate/Standar
d
EN
1
3
240
SINTEF 110-029
8
A
pp
rove
d
by
pp y
RWE P
o
w
e
r A
G
S
INTEF - NBL
Dust at 13
%
O2: 44 mg/Nm
³
Flue gas temperature: 350
°C
Nomina
l
h
eat output: 5,5
kW
Efficiency: 76%
Scan A/S DK 5492 Vissenbjerg
Minim
u
m
d
i
s
t
a
nc
e
t
o
c
o
m
bus
ti
ble
m
a
t
e
ri
als:
Si
d
e:
35
0 mm - Bac
k
: 2
5
0 mm - Front: 1000 m
m
CO emission at 13% O2
:
Fo
ll
ow assem
bl
y- an
d
instructions manua
l.
Use only recommended
f
uels
.
Monta
g
e- un
d
Be
d
ienun
g
san
l
eitun
g
b
eac
h
ten.
V
erwenden Sie nur empfohlene Brennstoffe
.
1000 06-2010
Scan A/S DK
549
2 V
i
ssen
bj
er
g
0,11
%
1338 mg/Nm
³
S
c
h
w
e
i
z
G
erman
y
y
y
LRV 1
1
BStV 1
VKF N 18900
FSPS-Wa 176
9
-EN
RWE P
o
w
e
r A
G
RWE Power A
G
Scan 58-9 & Scan 58-10 with high top
Scan 58-9 + Scan 58-10 wit
h
h
i
gh
to
p
Freestanding room heater fired by solid fue
l
Stan
d
ar
d
:
Fue
l
type
:
Operat
i
on t
y
pe
:
The appliance can be operated in a shared flue.
y
C
ountr
y
E
N 1
3
240 EC no. 90
358
62
0
W
oo
d
Int
e
rm
i
tt
e
n
t
E
U
R
Norway
y
A
us
tri
a
C
l
ass
ific
a
ti
on
Int
e
rm
i
tt
e
nt
K
lasse
2
C
erti
f
icate/Standar
d
EN
13240
SINTEF 110-02
98
1
5
a B-V
G
A
pp
rove
d
by
pp y
RWE Power A
G
S
INTEF - NBL
RWE Power A
G
Dust at 13
%
O2: 44 mg/Nm³
Flue gas temperature: 300
°
C
Nomina
l
h
eat output: 5,5
kW
E
ff
iciency: 80
%
A
n
g
aben für Österreic
h
Wärme
l
eistungs
b
ereic
h
: 3,0 - 6,7
kW
Brennstoffwärmeleistung: 8,4 k
W
Zulässige Brennstoffe: Scheithol
z
Prüfbericht:
F
SPS-Wa 176
9
-A
Scan A/S DK 5492 Vissenbjerg
Minim
u
m
d
i
s
t
a
nc
e
t
o
c
o
m
bus
ti
ble
m
a
t
e
ri
als:
Si
d
e:
35
0 mm - Bac
k
: 2
5
0 mm - Front: 1000 m
m
CO emission at 1
3
% O2
:
Fo
ll
ow assem
bly
- an
d
instructions manua
l.
Use only recommended fuels
.
Montage- un
d
Be
d
ienungsan
l
eitung
b
eac
h
ten.
V
erwenden Sie nur emp
f
ohlene Brennsto
ff
e
.
1000 06-2010
Scan A/S DK
549
2 V
i
ssen
bj
er
g
0,11
%
1338 mg/Nm
³
S
c
h
w
e
i
z
G
erman
y
y
y
LRV 1
1
BStV 1
VKF N 18900
FSPS-Wa 176
9
-EN
RWE P
o
w
e
r A
G
RWE P
o
w
e
r A
G