23 • White point calibration
ColorQuartet 5.0 Pro
198
White point calibrating your drum scanner
NOTE: If the scanner has a removable drum, carry out focus calibration first, if necessary. This
should also be done for the ScanMate 3000 the first time you calibrate.
1 • Make a preview scan.
2 • When the Preview window appears, draw a crop frame that is about 10-20 mm (0.5"-1")
square, making sure that it includes only the clear drum or white paper.
3 • Choose Calibrate White from the Calibration menu.
4 • Click on OK to confirm.
• Transmission: scan a clear area of the drum.
• Reflection: scan a piece of paper that is at least as white as the whitest part of
the originals you plan to scan.
The calibration will automatically be carried out, and a message will
appear to tell you whether it was successfully completed.