User manual
15 • ScanFlow & MouseFree • Procedures
ColorQuartet 5.0 Pro
146
ScanFlow System • Scanning
When the ScanFlow System is activated, you can place any previewed template or drum in the
scanner at any time. If the template or drum contains images that have already been sent to the
Job Queue with the Ready to Scan and Do Jobs commands, they will be scanned as soon as you
close the lid of the scanner (flatbed scanners) or click on Resume in the CQscan
window (drum
scanners).
1 • When you are ready to scan a template or drum, open the lid of the scanner (flatbed scan-
ners) or click on the Pause button in the CQscan window (drum scanners).
2 • Place the template or drum in the scanner and close the lid. (Drum scanners: after the
drum code has been read, click on the Resume button in the CQscan window.)
TIP
S:
• Remember to choose Do Jobs from ColorQuartet’s Scan menu when you have finished prepar-
ing a preview for scanning This moves the jobs into CQscan’s Job Queue.
• Drum scanners: Especially on older drums, the bar code may start to wear off and become dif-
ficult to read. To order a new bar code label from your authorized Purup-Eskofot dealer,
please state the drum number, which can be found by looking at the two digits before and two
• If another batch is being scanned, scanning will stop immediately, and the
current job will be put back into the queue so it can be scanned later.
• Scanning will immediately begin.
In the CQscan window, the job names will move one by one from the Job
Queue list to the Status list and then disappear.
• In ColorQuartet’s J
obs window, the same jobs will appear with the status
Queued as long as they are in the Job Queue list and Scanned after scanning
is completed.
• If nothing happens when you close the lid of the scanner or click on the
Resume button, the template or drum does not contain any jobs that are
currently in the Job Queue.