Service manual
7020
CAUTION: If a parallel data transfer is to be executed with the ISW Trns program, the ECP mode
setting of the PC parallel port should be cleared. ISW Trns does not support parallel data
transfers. If a parallel data transfer is launched with the PC set in ECP mode, the transfer could be
aborted by an error occurring in between. It would be necessary, therefore, to [[disable ECP mode|
IMAGE v:\bitmaps\ISW011.bmp SCROLL]] before run ISW Trns on a PC with the ECP setting.
UPDATING
[[Update the ROM data on each control board using ISW Trns.| IMAGE v:\bitmaps\ISW014.bmp
SCROLL]]
*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]
FK101, how to program which paper tray all reports print from.DESCRIPTION: SOLUTION ID:
91778
SOLUTION:
To program the paper tray for any of the available reports, perform the following:
1. Select copy mode and press the help key.
2. Select Key-Ope Mode.
3. Enter 4 digit key operator password.
4. Select option 2 FAX
5. Select Report Output Set.
6. Scroll to second page of options.
a. PAPER TRAY FOR REPORTS will be highlighted.
7. Touch edit until desired tray is displayed.
a. Tray 1
b. Tray 2
c. Tray 3
d. Tray 4
e. Bypass
8. Touch Back/Return until standard copy screen is displayed.
USAGE:
9
F35-6 occurs at power up.DESCRIPTION: SOLUTION ID:
116069
SOLUTION:
CAUSE: Fixing heater/2 failed.
SOLUTION: To check the fixing heater /2 lamp, perform the following:
1. Access the 47 multimode (power the machine ON, while holding down on the 4 and 7 keys)
input code 45, press *-2-*.
2. Press the print button and see if the fixing heater/2 comes ON.
3. If the lamp does not come ON, replace the fixing lamp/2 (p/n 26NE83030).
USAGE:
9
Code 0004 occurs when running L-DetectDESCRIPTION: SOLUTION ID:
121159
SOLUTION:
CAUSE: A wire on the TDS sensor is broken.
SOLUTION: Remove the developer unit and inspect the TDS sensor wires to see if they are
pinched or broken.
USAGE:
9
J32-2 when duplexing.DESCRIPTION: SOLUTION ID:
124471
SOLUTION:
CAUSE: Conveyance drive gear in the fuser was installed backwards.
SOLUTION: Install the conveyance drive gear (p/n 26NA53450) correctly so that the paper is
driven down after the turnaround from the fuser.
USAGE:
9
DF314, E89-1 when using the RADF.DESCRIPTION: SOLUTION ID:
126633
SOLUTION:
CAUSE: Worn RADF wire harness.
SOLUTION: Replace the RADF wire harness (p/n 13GL90041).
USAGE:
9
The fixing web has completely advanced and is unattached from its roller prior to reaching
its estimated life expectancy.
DESCRIPTION: SOLUTION ID:
129444
SOLUTION:
CAUSE: The fixing counter (fixing web) was reset.
SOLUTION: Reset the fixing counter only when the cleaning web is replaced.
USAGE:
9
F51-6 code at power up. 24V DC is present at CN22-5 on the PRDB.DESCRIPTION: SOLUTION ID:
135129
SOLUTION:
CAUSE: Failed write unit.
USAGE:
9
28
Copyright 2005, Konica Minolta Business Solutions U.S.A., Inc.
May 2005