Service manual
7020
Background, streaks, toner misting, and/or excessive toner build up in the recycler unit.DESCRIPTION: SOLUTION ID:
95303
SOLUTION:
CAUSE: Failed toner recycling auger assembly attached to the rear of the drum carriage and/or
insufficient sealing of the developing unit causing toner misting onto the charging corona unit.
SOLUTION: Install the following:
1. Toner Packing Countermeasure Kit (p/n 26NA-K040FOC).
Note: Technical Bulletin 9A indicates that only 4 mylars are to be removed from collect cover/C.
This is incorrect, remove ALL mylars from collect cover/C.
2. Charging Corona Soilage Countermeasure Kit 1 (p/n 26NA-K010FOC) and Kit 2 (p/n
26NA-K020FOC).
3. Due to timing changes in M1 (Main motor) it is critical that level 32 System firmware and level
31 Image firmware or higher be installed when performing this modification.
Notes:
1. Please refer to [[7020/7025/7030/7035 Technical bulletin # 9 (MODIFICATION KITS)| URL
http://techweb.konicabt.com/tpm/media/7020-25-30-35-tb09a.pdf]] for the complete installation
procedures and for the proper parts ordering procedures. To view this PDF hyperlink, Acrobat*
Reader must be installed. Acrobat Reader can be downloaded for free from the Adobe* Web site
at: [[http://www.adobe.com/products/acrobat/readstep2.html| URL
http://www.adobe.com/products/acrobat/readstep2.html]]
2. Be sure to reset drum and developer/PM counters when either is replaced.
a. Drum counters can be reset in both 36 mode (8. COUNTER CLEAR) and 25 mode fixed parts
counter (4. PARTS COUNTER).
b. When developer is replaced both PM counter [25 mode (2. PM COUNT/CYCLE)] and
developer fixed parts counter [25 mode (4. PARTS COUNTER)] should be reset.
3. To help alleviate unnecessary copy quality problems, instruct customer to pull both the small
green corona cleaner and the write unit slit glass cleaner several times whenever toner is replaced.
CAUTION: The L-detection adjustment must never be performed on used developer. L-detection
adjustment must only be performed after developer is replaced and before any copies are made.
Developer will overtone if L-detect is performed more than once on the same developer or if copies
are made prior to performing L-detect on new developer.
4. If black lines or streaking continue after installing Technical bulletin # 9 (MODIFICATION KITS),
clean or replace the Charge wire (p/n 26NA25060) and Charging control plate (p/n 26NA25160) as
necessary.
*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]
USAGE:
772
DF314, intermittent line(s) on copies from lead-to-trail.DESCRIPTION: SOLUTION ID:
91308
SOLUTION:
CAUSE: Paper dust, white out, etc. is being deposited and adhering to the RADF original slit glass
(p/n 26NA61131). This will cause a black line to occur, in a lead-to-trail direction, when copying
from the RADF.
SOLUTION: To help minimize this problem, perform the following:
1. Replace the original slit glass (p/n 26NA61131) with the new style 7145 original slit glass (p/n
40LA-6280). The 7145 original slit glass (p/n 40LA-6280) has a fluorine coating on the surface of
the glass to help prevent debris from adhering to the glass. When installing the original slit glass
(p/n 40LA-6280), ensure that the black dot mark is on the right rear side.
2. Thoroughly clean the original slit glass (p/n 26NA61131), located to the left of the original scale
plate, with a clean soft cloth dampened slightly with water, or an anti-static cleaner.
3. Apply a couple of drops of Rain-X* and rub into the slit glass, this may reduce the occurrence of
foreign debris sticking to the slit glass.
4. Check the RADF height adjustment and adjust as necessary. The procedure can be found on
either page E-2 of the DF314 installation instructions or in the 7020/7025/7030/7035 service
manual (3/2001) page 4-88.
a. The DF314 reading roller (p/n 13GL45520) may apply too much pressure to the slit glass if
the DF314 height is adjusted too high. This added pressure might contribute to debris adhering to
the slit glass.
b. After performing the height adjustment, it may be beneficial to re-adjust the height positioning
screw approximately 1/2 to 3/4 of turn counterclockwise. The position of the white pointer should
slide down to the left of center slightly; this will relieve additional pressure away from the slit glass
by the reading roller.
CAUTION: Adjusting the RADF height too high may cause RADF jamming at the slit glass area or
blurred copies.
5. Adjusting the READ POINT ADJUSTMENT, in the 36 mode, may also help to minimize this
problem.
a. The READ POINT ADJUSTMENT moves the first mirror to a different home position and
consequently a different position under the slit or scan glass. By moving the read point of the first
mirror and adjusting RESTART TIMING, you can effectively move the read point of the scan glass
so it is not directly under the DF314 reading roller. This is the area that appears to be the most
susceptible to slit glass contamination.
b. The READ POINT ADJUSTMENT procedure can be found in the 7020/7025/7030/7035
USAGE:
81
2
Copyright 2005, Konica Minolta Business Solutions U.S.A., Inc.