Service manual
7020
cable that is connected to the master channel of the PC or IP controller. Power is supplied by the
IP/PC's power supply through a standard power connector.
3. Use a Microsoft Windows 98 boot disk which can be created on a Windows 98 workstation.
4. Connect the hard drive to the 40-pin connector on one side of the adapter and connect the
IP/PC's IDE cable to the 44-pin connector on the other side of the adapter. Ensure that [[Pin 1 on
the IDE connector and hard drive| IMAGE V:\BITMAPS\IP411_HD_connect.bmp SCROLL]] is
connected to [[Pin 1 on the adapter| IMAGE V:\BITMAPS\IP411_HD_connect1.bmp SCROLL]].
5. Insert the 98 Boot disk into the floppy drive of the IP/PC, reconnect the IP/PC power cord, and
power ON the IP/PC.
6. Once the IP/PC boots from the floppy, press return at the date and time prompts to get to the A:
prompt.
7. Use FDISK to create a primary DOS partition and set it as active.
WARNING: Do not use large disk support.
8. Format the newly-created partition with the /s switch to transfer system files.
=================================C A U T I O
N=================================
If the hard drive is not connected to the IDE master channel, and is not configured to be the
MASTER
drive, the setup program will format whatever drive is connected and setup as the MASTER
drive.
===========================================================================
==
9. Remove the hard drive from the PC and reinstall it the IP unit. Allow the IP and main body to
completely boot or this process will have to be repeated.
*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]
DF314, RADF FAILURE PLEASE CALL SERVICE message.DESCRIPTION: SOLUTION ID:
102090
SOLUTION:
PROBABLE CAUSES:
1. The ADF CB has failed.
Reseat the connectors on the ADF CB and loosen ties wraps on wiring harness to ensure proper
communication is taking place between the ADF and the main body. Reflash the files in the ADF.
If problem persists, replace ADF CB (p/n 13GL-9010).
2. Failure of the original reversal motor (M303). When checking the document feeder
photosensors, all operate properly in diagnostics.
To verify the operation of M303, perform the following:
a. Power the machine OFF.
b. Access the 47 multimode (power the machine ON while pressing the 4 and 7 keys), output
code 60, P-2-3 to verify the operation of M303.
c. If motor drive does not occur, it is necessary to replace M303 (p/n 13GL80030). It may also
be necessary to replace the RADF CB (p/n 13GL-9019) if the motor damaged the board.
Notes:
I. If the new ADF CB needs to be flashed, DF314 write protection must first be turned OFF.
To turn OFF DF314 write protection, perform the following:
A. Power the copier OFF.
B. Access the 25 mode (power the copier ON, while pressing the 2 and 5 keys).
C. Select [ 1. SOFTWARE SW].
D. Using the up/down arrows, scroll to software switch 23-6.
E. Select ON.
F. Power the copier OFF/ON to return to normal copy mode.
II. System control firmware level 32 CGDO (minimum level) must be installed for the
dipswitch to function.
III. Refer to the [[ADF serial number, DF Control Board, firmware version and model
compatibility matrix| URL http://techweb.konicabt.com/tpm/media/t20030054a1e.pdf]].
IV. To view the PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloaded
for free from the Adobe* Web site at: [[http://www.adobe.com/products/acrobat/readstep2.html|
URL http://www.adobe.com/products/acrobat/readstep2.html]]
*[[Trademark ownership information| FILE V:\TEXT\TRADEMRK.TXT NEW]]
USAGE:
28
F26-1 at power up.DESCRIPTION: SOLUTION ID:
112220
SOLUTION:
PROBABLE CAUSES:
1. The TDS (Toner Density Sensor), in the developing unit, has detected a depletion of toner.
Note: This may have been caused by the customer making an excessive amount of copies while
the machine was out of toner. It may also be caused by a bound toner addition system.
Clean all toner from the toner recycle and toner supply assemblies. Confirm that the gear mesh
between the toner supply auger drive gear and toner supply motor (M4) is flush. If toner supply
conveyance is normal and the toner cavity is empty, install a new toner cartridge (Item #950236)
USAGE:
28
10
Copyright 2005, Konica Minolta Business Solutions U.S.A., Inc.
May 2005