Specifications
16 Specifications HW400p/M Technical Reference - 1.0, March 6, 2002
3-7. Mean Time Between Failures
The part failure source rate was calculated in accordance with the TELCORDIA
TECHNOLOGIES Specification TR-332, version 6. This is based on an ambient
temperature of 40 °C in a benign controlled environment, using Quality Level
II parts.
The mean time between failures for the HW400p/M is greater than or equal
to 275,000 hours.
3-8. Compliance
Industry standards compliance HW400p/M complies with the following industry standard specifications:
• PCI Special Interest Group, “PCI Local Bus Specification,” Rev. 2.1,
June 1995.
• IEEE P1386 Common Mezzanine Card Standard.
• IEEE P1386.1 Physical and Environmental Layers for PCI Mezzanine
Cards.
• GR-63-CORE, “Network Equipment-Building Systems (NEBS)
Requirements: Physical Protection,” Issue 1, October 1995.
3-9. Certifications
All certifications described in the following sections are pending.
Safety Tested to Comply with
IEC 60950:1991+A1:1992+A2:1993+A3:1995+A4:1996
(CB Report Reference No. XXXXXX - PENDING)
UL 1950 Edition 3 and cUL.
This adapter is a UL-listed accessory (UL File No.
PENDING) and is for use only with UL-listed computers, workstations, network
servers, etc. that have installation instructions that detail how to install
adapter cards.
Emissions
EN 50082-1 and EN55022 (Report JTN PENDING).
CC Part 15, Subpart B.
This equipment generates, uses and can radiate radio
frequency energy, and, if not installed properly and used in accordance with
instructions contained in this manual, may cause harmful interference to
radio communications. This device was tested and found to comply with the
limits for a Class A Computing Device, in accordance with the specification in
Part 15 of FCC Rules.
Operation of this equipment in a residential area is likely to cause harmful
interference. The user will be required to correct the interference at his or her
own expense.