Operating instructions
The following requirements apply to a single server two wire deployment.
• M1 is used for management.
• A1 is used to communicate with IP Office.
• B1 is used to communicate with the endpoints.
• M1, A1, and B1 all require an IP address. M1 cannot be on the same subnet as A1 or
B1.
• If A1 and B1 are on same subnet, you can do a one-wire deployment and use A1 only for
data. M1 is still required for management.
•
• Since the Portwell CAD has fewer interfaces, M2 or B2 are not listed on the back. M1,
A1, and B1 are the ports used on Portwell SBC hardware as well. All network interfaces
on the SBC are auto negotiate, so the switch or router ports that the SBC connects to
must also be set to auto negotiate.
Creating a backup
Backup the empty SBCE configuration. This enables you to start again from scratch.
Procedure
1. Login to the SBCE Control Center as Admin.
2. In the navigation tree on the left, select Backup/Restore and then select the
Snapshots tab.
3. Click Create Snapshot.
4. Enter a description and then click Create.
5. Click Download and save the file locally.
Next steps
When you have finished the configuration, create another snapshot. See Administering Avaya
Session Border Controller for Enterprise for a procedure to configure automatic backup to an
SFTP server.
Configuring Session Border Controller Enterprise for IP Office Remote Workers
12 Configuring the Avaya Session Border Controller for IP Office Remote Workers September 2013