Installing the Temperature Sensor
(for illustrative purpose only)
Figure 1
TEMP
Terminal Block
On a surface where there is no obstruction below it.
Height has to be 1.2-1.5 meters above the floor.
It should be away from the steam head so that the steam
will not hit the sensor directly.
The sensor has an integrated 9-meter cable. If longer
cable is needed, please consult your SAWO technician.
An 8mm hole is required to insert the temperature
sensor. Do not create bigger or smaller hole. Clean
the hole before inserting the sensor.
Make a hole in the cable lead-in on the side of
the generator to pull the cable through. Connect
the cable in the terminal block marked as
"TEMP". See figure 2.
The temperature sensor has to be installed:
a.
1.
2.
3.
b.
c.
4.5 kW | 6.0 kW | 7.5 kW
9.0 kW
380-415V
3N~
380-415V
3N~
CONTROL
C
CONTACTOR
HEATING
ELEMENT
C
S
WATER
FEED
SOLENOID
VALVE
CONTROL
BOARD
CONTROL
POWER INPUT
GROUND
230VAC in
FAN
SCENT PUMP
24VAC IN
CONT. DRAIN FILL
PE
PROBE1
PROBE2
PROBE3
COMMUNICATION
LIGHT
SWITCH
L
NG
CONTACTOR
FUSE
NTC2
TRANSFORMER
L2
NG
L1L3
HEATING
ELEMENT
C
CONTACTOR
POWER INPUT
GROUND
L3
L2
L1 N G
TRANSFORMER
S
WATER
FEED
SOLENOID
VALVE
CONTROL
BOARD
230VAC in
FAN
SCENT PUMP
LIGHT
24VAC IN
CONT. DRAIN FILL
PE
PROBE1
PROBE2
PROBE3
COMMUNICATION
SWITCH
FUSE
NTC2
220-240V
1N~
9.0 kW | 12.0 kW | 15.0 kW
380-415V
3N~
C
CONTACTOR
HEATING
ELEMENT
S
WATER
FEED
SOLENOID
VALVE
CONTROL
BOARD
CONTROL
POWER INPUT
GROUND
230VAC in
FAN
SCENT PUMP
24VAC IN
CONT. DRAIN FILL
PE
PROBE1
PROBE2
PROBE3
COMMUNICATION
SWITCH
L3
L2
L1 N G
FUSE
NTC2
TRANSFORMER
TEMP
SENSOR
AUTOMATIC
DRAIN
FUSE
NTC2
TEMP
SCENT
FAN
PUMP
TEMP
SWITCH
(24VAC)DRAIN
(230VAC) LIGHT
(12VDC)ILL
Before installation main supply of the generator must be switch off from the
circuit braker.
TEMP
16
The temperature sensor comes along with the SAWO steam generator. It is recom-
mended to use only Sawo temperature sensor with Sawo generator as it may other-
wise not function correctly.Temperature sensor wiring should not be routed near
power cables or hot areas as it may cause electronic interference or damage to the
wires.