Technical data
11
For illustrative purposes only.
Water Filter /
Softener
Plumbing
Water Supply
Connecting Water Filter and Softener
i
Steam Generator
Side view
showing element
access panel
Overpressure
Valve
Steam
Outlet Valve
Thread:
1/2” BSP
Thread:
3/4” BSP / 1” BSP
Automatic
Drain
Water Inlet
Water Inlet
Power
Switch
The plumbing has to be done by a qualified licensed plumber. Plumbing should be in
accordance with national or local codes. Use unions for piping connections. Use only
prescribed brass piping or copper tubing. Never use black or galvanized pipe for the
plumbing as it can easily crack or damage.
Provide a shut off valve on the water source for the steam generator. Turn off the inlet
water line before installing the unit. Recommended water pressure is 1 to 3 bar and
maximum water pressure without water filter/softener is 8 bar. Water softener is recom-
mend to use.
Attaching the Autodrain
Attach the Brass tee into the outlet.
Attach the autodrain to the brass tee.
Open the cover of the steam
generator.
Put the wire through the hole on the
side of the steam generator.
Cover back the steam generator.
1.
2.
3.
4.
5.
6.
Drain
Drain valve is provided for maintainance. Set drain connection for your steam
generator according to national or local plumbing requirements.
Steam Head
downward
position
Steam room wall
min. 3mm
Steam Head
Top View
3
5
Terminal Block
DRAIN
Place the steam head on a safe area
where bathers cannot get in contact
with it as it can get very hot. The
steam head must be facing down-
wards. A teflon tape or equivalent
needs to be used on the thread for
tightening it. Avoid using a wrench to
tighten the steam head as it might get
scratched.
Steam Outlet
The steam must move in a continuous flow to the steam room. Do not istall valves on
the steam line. Use insulated, rated 120ºC or higher, brass pipe or copper tubing for
steam line to connect to the steam head as permitted by codes. Slope the steam line
height by 20mm per meter towards the steam head to avoid trapping of the condensate
and eliminate steam trap that blocks the flow of the steam.
Steam Guard Overflow
Connect the wires in the terminal
block to its label.
Brass Tee
4
Twist
1
2
Autodrain
DRAIN
Steam Supply
Use a Teflon or a sealant
for the pipe threads
(1/2” BSP)
The overflow safety guard activates when there is an overpressure in the the steam
line. It automatically opens and releases the pressured steam. When this happens,
please check your steam line for servicing.
12