Technical data

Steam Generator Series Connection
21
DIP Switches in the Steam Generator
Standby time
Standby
Duration
Mode
Switch
6
Switch
7
Switch
8
4h 0 0
6h 0 0
12h 0 1
18h 0 1
0
1
0
1
Unlimited 1 0 0
4h 1 0 1
4h 1 1 0
4h 1 1 1
Slave
No.
Switch
1
Switch
2
100
201
310
411
Dipswitches for other Functions
Dipswitches for
Naming Slaves
1 = ON
= OFF
0
Possible errors are:
Troubleshooting
Check the wire between the fuse and the
control unit. Fuse has probably overheated.
The reason for it needs to be discovered
before using the steam generator again. A new
fuse is needed.
If no problem can be found, contact the retailer.
Temperature fuse defect.E5
Temperature sensor 1
not connected.
Check the wire between the sensor and the
control unit.
If there is no problem with the wires and they
are correctly installed, check the sensor.
If no problem can be found, contact the
retailer.
E1
Temperature sensor 1
short circuit.
E2
Temperature sensor 2
not connected.
E3
Code Problem Solution
Temperature sensor 2
short circuit.
E4
Session Time
Session
Time
Switch
2
Switch
3
Switch
4
10min 0 0
15min 0 0
20min 0 0
30min 0 0
0
0
1
1
45min 0 1 0
1h 0 1 0
2h 0 1 1
4h 0 1 1
Switch
5
0
1
0
1
0
1
0
1
6h 1 0 0 0
8h 1 0 0 1
12h 1 0 1 0
18h 1 0 1 1
Unlimited 1 1 0 0
10min 1 1 0 1
10min 1 1 1 0
10min 1 1 1 1
22
Dipswitch
No.:
Function
On Off
8Cabin Light
7
6
5
4
3
2
1
30-55°C
Dimmer option
enabled
Dimmer option
disabled
Present
Present
Connected
Yes
30-50°C
Not Present
Not Present
Not Connected
No
Fan
Scent Pump
Auto Drain
Temperature range
Slave Unit
Slave Number
Slave Number
Standby time can be set according to
user preferences by setting dip
switches on the power controller board
Session time can be set according to user
preferences by session dip switches on the
power controller board.
If an error occurs, the steam generator will be switched off. There will be a warning beep
to alarm the user every 2 seconds. The code for the error will be displayed blinking in the
control panel, see the table below.
Please note, only a qualified electrician or maintenance personnel are allowed to make
the service operations and repairs!
If an error occurs in one of the slave units, error message is followed by slave number. For
example: E1 -> S2 -> E1 ->S2... Pressing ON/OFF button disables the slave and rest ot
the generators can operate normally.
DIMMER
FAN
SCENT PUMP
DRAIN
TEMP
SLAVE
STANDBY
SESSION
Steam Generator
Control
Master
Steam Generator
DIP SW
3 = OFF
DIP SW
3 = ON
2 = OFF
1 = OFF
DIP SW
3 = ON
2 = ON
1 = OFF
Slave 1
Steam Generator
Slave 2
Steam Generator
Slave 3 Slave 4
RJ12 Cable