5. FIRE-FIGHTING MEASURES
Flammability Limit in Air
Upper flammability limit:
No information available
Lower flammability limit:
No information available
Self ignition
No information available
Ignition temperature
No information available
Minimum Ignition Energy
No information available
Impact Sensitivity
No information available
Hazardous combustion products
Carbon monoxide. Carbon dioxide (CO2). Hydrogen chloride. Hazardous decomposition
products due to incomplete combustion. Oxides of sulfur. Nitrogen oxides (NOx).
Hazardous Organic Compounds. Aldehydes. Hydrogen cyanide. Hazardous metal fumes
and oxides. Acrylonitrile. Styrene.
Suitable extinguishing media
Water spray (fog). Carbon dioxide (CO2). Foam. Dry chemical.
Unsuitable extinguishing media
Do not scatter spilled material with high pressure water streams.
Specific hazards arising from the chemical
Combustible material. In the event of fire and/or explosion do not breathe fumes. Thermal decomposition can lead to release of
irritating and toxic gases and vapors. Avoid creating dust. Fine dust dispersed in air in sufficient concentrations, and in the
presence of an ignition source is a potential dust explosion hazard. Runoff may pollute waterways. Dispose of fire debris and
contaminated extinguishing water in accordance with official regulations.
Explosion data
Sensitivity to Mechanical Impact
None.
Sensitivity to Static Discharge
None.
_____________________________________________________________________________________________
Protective equipment and
precautions for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH
(approved or equivalent) and full protective gear.
Flash point
Page 4 / 12