Assembly Instructions
33
Problem Possible Cause
Corrective Action
Excessive flare-up.
1.
LP tank is empty.
2.
Burner is not aligned with
the
control valve.
3.
Gas supply is not sufficient.
1.
Refill the LP Tank.
2.
Install the burner correctly.
3.
Check the gas supply hose
and
make sure there are no
leaks and
no knots.
Low heat with the knob
in “MAX” position.
1.
Ports are blocked.
2.
LP tank has run out.
1.
Clear ports of any
obstructions.
2.
Refill the LP tank.
Low heat, LP gas.
The propane regulator assembly
incorporates an excess flow device
designed to supply the
grill with
sufficient gas flow.
Rapid changes in pressure can trigger
the excess flow device,
providing a
low flame and low
temperature.
Please follow these instructions:
1.Make sure all burners are “OFF”.
2.Open the tank valve and wait 5
minutes.
3.Light the burner one at a time
following the lighting instructions listed
on the door liner and Page24.
Burner Burner










