Service manual

FACTORY RESET (NVRAM CLEAR) 12 March 1999
G031/G032 10-8 SM
3. SERVICE TABLES AND PROCEDURES
3.1 FACTORY RESET (NVRAM CLEAR)
When the machine or the network interface board has moved to a different
location, reset the NVRAM contents to the factory defaults as follows.
1. Remove the network interface board and the NIB cover (4 screws). Then
change the FACT jumper setting as shown above.
2. Install the network interface board and turn on the machine.
3. The green LED flashes 3 times, then the amber and green LEDs light
alternately (once per second).
4. Turn off the machine and remove the network interface board.
5. Reset the jumper setting to the default, and reassemble the machine.
6. Turn on the machine.
Factory Reset
Default
OP1 OP7
Bypass
Fact
Fact
ON
G919M500.WMF
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA