Operating instructions

Remote Maintenance by Telnet (mshell)
65
5
Note
When using the TCP/IP protocol, type ip followed by a space and then the
IP address.
When using the IPX/SPX protocol, type ipx followed by a space, the IPX
address followed by a decimal and then the MAC address of the Network
Interface Board.
The following is an example of how to configure registration number 3 with
the IP address 192.168.15.16.
msh> snmp 3 ip 192.168.15.16
The following is an example of how to configure registration number 3 with
the IPX address 7390A448, and the MAC address 00:00:74:62:5C:65.
msh> snmp 3 ipx 7390A448.000074625C65
Changing the password
Use the passwd command to change the remote maintenance password.
Important
Be sure not to forget or lose the password.
Note
The default factory password is “password”.
A
Type “passwd”.
msh> passwd
B
Type the current password.
Old password:
C
Type the new password.
New password:
Note
The password must consist of 3 to 8 alphanumeric characters and symbols.
Upper and lower case characters are considered unique. For example, R is
different from r.
The password is the same as that used in the configuration of the Network
Interface Board using a Web browser and that used in NIB Setup Tool. If
you change a password on the mshell, the other passwords are also
changed.
D
Type the new password again.
Retype new password: