Service manual

1.3.14 Potential Control in Abnormal Sensor Conditions
You can check the result of the process control self check with SP 3-975.
One of the following codes will be displayed.
SP3-975 Process control self check result
Code
No.
Error
SP No.
(Displays
Values
Only)
Potential Causes Note
01 No error
80
V
SG
_ave
Error
1. ID Sensor
2. Dirty ID Sensor
3. Drum
Agitate the developer to
charge up the toner
Check the ID sensor
81
V
SG
_ptn
Error
1. ID Sensor
2. Dirty ID Sensor
3. Drum
Agitate the developer to
charge up the toner
Check the ID sensor
85
Vmin (color)
Difference
Error
3-910-1
(Bk)
3-910-2 to
3-910-4
1. ID Sensor
2. Dirty ID Sensor
3. Drum
4. Development Unit
New or fairly new
machine: ID sensor or
electrical noise
Check the development
unit or drum unit.
90
Development
Potential
Calibration
Error
3-4-1 (Co-
efficient)
3-4-2
(Intercept)
1. Faulty Drum Potential
Sensor
2. Faulty High Voltage
Supply Board (V
B
)
3. Faulty Drum (Pin Hole)
4. Drum Grounding Shaft
not properly connected
5. Electrical Noise
6. Residual Voltage on the
Drum
Not enough waiting time
allowed before the
forced process control
self check.
Check the drum
grounding shaft hood
inside the drum.
Check the output voltage
at the potential sensor
(TP213) on the printer
main board with a digital
oscilloscope (during the
potential calibration).
91
V
D
Error at
Home
Position
1. Improper installation of:
-Charge Corona Unit
-Drum Potential Sensor
-Drum
Check that the following
are installed correctly:
-Development Unit
-Drum Unit
-Charge Corona Unit
Detailed
Section
Descriptions
PROCESS CONTROL
SM 2-11 A166/A187/A189
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA