Service manual

1st 2nd 3rd Display Function
Default,
( ): For Europe
Settings/Range Comments Report
3 957 P-Ctrl Data Tx
Sends the data concerning
process control through the serial
port (the optics fiber) to the P/C.
00 to 5
Do not change the factory
setting.
3 964 Dev. Agitation Result
Displays the result of the most
recent developer agitation.
-
01: Success
Others: Error
See the developer agitation
error code table in section 2.
(1. 4. 6.)
3 973 P-Ctrl Self Chk Interval
Sets the interval for process
control.
150 0 to 200 (copies)
Do not change the factory
setting.
3 974 Toner Max M/A Target Sets the target maximum M/A 1100 800 to 1300
Do not change the factory
setting.
3 975 P-Ctrl Self Chk Result
Displays the result of the most
recent process control self check.
-
01: Success
Others: Error
See Detailed Section
Descriptions - Process
Control for details of the
various error codes that are
displayed.
This should be checked
every time after switching
the machine on after doing
the following:
Replacing the developer,
drum, ID sensor, drum
potential sensor, or charge
corona unit
Cleaning the ID sensor or
charge corona unit
SCANNER
4 8 Subscan Magnification Adjusts the scanner motor speed. 0 -0.9 to +0.9 (%)
Do not change the factory
settings.
4 10 Lead Edge Regist:Scanng
Adjusts the vertical registration for
the scanned image by adjusting
the laser exposure start timing.
0 -9.0 to +9.0 (mm)
Do not change the factory
settings.
4 11 Sd to Sd Regist:Scanng
Adjusts the horizontal registration
for the scanned image by
adjusting the laser exposure start
timing.
0 -6.0 to +6.0 (mm)
Do not change the factory
settings.
PROCESS CONTROL
SCANNER
SM APPENDIX 11-37 A166/A187/A189