Service manual

1st 2nd 3rd Display Function
Default,
( ): For Europe
Settings/Range Comments Report
2 952 1 Tnr End Rec Coef:K
Sets the coefficient used to
calculate the toner supply ratio for
toner end recovery for Bk. The
greater this coefficient is, the
smaller the toner supply is.
8 0 to 1000
Do not change the factory
setting.
2 952 2 Tnr End Rec Coef:CMY
Sets the coefficient used to
calculate the toner supply ratio for
toner end recovery for C, M, Y.
The greater this coefficient is, the
smaller the toner supply is.
6 0 to 1000
2 953 1 Max Tnr Rec Ratio:K
Sets the maximum toner supply
ratio for Bk. This ratio is the
percentage of the toner supply
motor on time at the maximum
duty of the toner supply motor.
60 0 to 100 %
Do not change the factory
setting.
2 953 2 Max Tnr Rec Ratio:CMY
Sets the maximum toner supply
ratio for C, M, Y. This ratio is the
percentage of the toner supply
motor on time at the maximum
duty of the toner supply motor.
60 30 to 100 %
2 954 1 Comp Dev Ptnl Sn Ptrn:K
Displays the development
potential for the ID sensor pattern
for Bk.
- -32767 to 32767
The value displayed is the
value of SP2-203-1,
plus/minus all correction
factors.
2 954 2 Comp Dev Ptnl Sn Ptrn:C
Displays the development
potential for the ID sensor pattern
for C.
- -32767 to 32767
The value displayed is the
value of SP2-203-2,
plus/minus all correction
factors.
2 954 3 Comp Dev Ptnl Sn Ptrn:M
Displays the development
potential for the ID sensor pattern
for M.
- -32767 to 32767
The value displayed is the
value of SP2-203-3,
plus/minus all correction
factors.
2 954 4 Comp Dev Ptnl Sn Ptrn:Y
Displays the development
potential for the ID sensor pattern
for Y.
- -32767 to 32767
The value displayed is the
value of SP2-203-4,
plus/minus all correction
factors.
PROCESS CONTROL
SM APPENDIX 11-33 A166/A187/A189
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA