Service manual
1st 2nd 3rd Display Function
Default,
( ): For Europe
Settings/Range Comments Report
2 203 1 Dev Ptnl ID Sn Ptrn:K Sets the development potential for
the ID sensor pattern for each
color (VB - VL at the ID sensor
pattern). Also see SP 2-954.
140 0 to 300 (V)
Do not change the factory
settings.
2 203 2 Dev Ptnl ID Sn Ptrn:C 140 0 to 300 (V)
2 203 3 Dev Ptnl ID Sn Ptrn:M 140 0 to 300 (V)
2 203 4 Dev Ptnl ID Sn Ptrn:Y 140 0 to 300 (V)
2 203 5 Dev Ptnl Ad ID Sn Ptrn:K
Adjusts the development potential
for the ID sensor pattern for each
color (VB - VL at the ID sensor
pattern). Only effective if SP
2-203-9 is at 1.
3
1:+20V 2:+10V 3:0V 4:-
10V 5:-20V
Do not change the factory
settings.
2 203 6 Dev Ptnl Ad ID Sn Ptrn:C Adjusts the development potential
for the ID sensor pattern for each
color (VB - VL at the ID sensor
pattern). Only effective if SP
2-203-9 is at 1.
3
1:+20V 2:+10V 3:0V 4:-
10V 5:-20V
Do not change the factory
settings.
2 203 7 Dev Ptnl Ad ID Sn Ptrn:M
2 203 8 Dev Ptnl Ad ID Sn Ptrn:Y
2 203 9 Dev Ptnl Compensation
Effects the adjustment of SP203-5
to SP203-8 for the development
potential. If this is set to 0, any
adjustment by SP2-203-5 to 8 is
ignored.
1 0: OFF, 1:ON
Do not change the factory
settings.
2 206 1 Target VB: K
Displays the target VB calculated
by the process control self check
for each color.
0 0 to 65535 (V)
2 206 2 Target VB: C 0 0 to 65535 (V)
2 206 3 Target VB: M 0 0 to 65535 (V)
2 206 4 Target VB: Y 0 0 to 65535 (V)
2 207 1 Forced Toner Spply:K
Performs the forced toner supply
mode operation for each color.
- ON: Start, OFF: C/S
2 207 2 Forced Toner Spply:C - ON: Start, OFF: C/S
2 207 3 Forced Toner Spply:M - ON: Start, OFF: C/S
2 207 4 Forced Toner Spply:Y - ON: Start, OFF: C/S
2 208 1 Forced Tnr Spply Times:K
Sets the number of forced toner
supply operations for each color.
10 0 to 20 (times)
2 208 2 Forced Tnr Spply Times:C 10 0 to 20 (times)
2 208 3 Forced Tnr Spply Times:M 10 0 to 20 (times)
2 208 4 Forced Tnr Spply Times:Y 10 0 to 20 (times)
PROCESS CONTROL
SM APPENDIX 11-31 A166/A187/A189
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA