Service manual

1st 2nd 3rd Display Function
Default,
( ): For Europe
Settings/Range Comments Report
2 101 4 Trail Mrgn (OHP/Thk)
Adjusts the blank margin at the
trailing edge in OHP/thick paper
mode.
2.5 0 to 10.0 (mm)
2 101 5 Trail Mrgn (Thk/Back)
Adjusts the blank margin at the
trailing edge for the reverse side
in thick paper mode.
5.0 0 to 10.0 (mm)
2 301 1 Belt Trans Current
Adjusts the belt transfer current to
compensate for various high
voltage supply boards (using the
drum current as a reference).
100
50 to 200 (
µ
A)
Do not change the factory
setting.
2 301 3 Belt Trans Crnt (1/4C)
Sets the first belt transfer current
for 2C and 4C mode.
50
10 to 600 (
µ
A)
Do not change the factory
settings.
2 301 4 Belt Trans Crnt (2/4C)
Sets the second belt transfer
current for 2C and 4C mode.
100
10 to 600 (
µ
A)
2 301 5 Belt Trans Crnt (3/4C)
Sets the third belt transfer current
for 4C mode.
100
10 to 600 (
µ
A)
2 301 6 Belt Trans Crnt (4/4C)
Sets the fourth belt transfer
current for 4C mode.
100
10 to 600 (
µ
A)
2 301 7 B.T.C. (1/2C)
Sets the first belt transfer current
for 2C mode when the belt is at
half speed.
100
10 to 600 (
µ
A)
Do not change the factory
settings.
2 301 8 B.T.C. (2/2C)
Sets the second belt transfer
current for 2C mode when the belt
is at half speed.
100
10 to 600 (
µ
A)
2 301 9 B.T.C. (1/2 Spd:3/4C)
Sets the third belt transfer current
for 4C mode when the belt is at
half speed.
180
10 to 600 (
µ
A)
2 301 10 B.T.C. (1/2 Spd:4/4C)
Sets the fourth belt transfer
current for 4C mode when the belt
is at half speed.
180
10 to 600 (
µ
A)
2 301 11 B.T.C. (1/1C):K
Sets the belt transfer current for
1C mode for Bk.
70
10 to 600 (
µ
A)
Do not change the factory
settings.
2 301 12 B.T.C. (1/1C):CMY
Sets the belt transfer current for
1C mode for CMY.
100
10 to 600 (
µ
A)
AROUND THE DRUM/BELT UNITS
SM APPENDIX 11-23 A166/A187/A189
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA