Service manual

1st 2nd 3rd Display Function
Default,
( ): For Europe
Settings/Range Comments Report
1 105 1 Set Hot Rllr.Tmp.Idling
Sets the target temperature of the
hot roller during idling. After the
setting is changed, the main
switch must be turned off/on.
145
130 to 170 (
°
C)
Do not input a value higher
than 167
°
C. The thermofuse
opens at 167
°
C.
1 105 2 Set Hot Rllr.Tmp.Std by
Sets the target temperature of the
hot roller during stand-by.
160
130 to 170 (
°
C)
1 105 3 Set Hot Rllr.Tmp.Nrml:FC
Sets the target temperature of the
hot roller during copying with
normal paper in full color mode.
150
130 to 170 (
°
C)
Do not input a value higher
than 167
°
C. The thermofuse
opens at 167
°
C.
1 105 4 Set Hot Rllr.Tmp.OHP:FC
Sets the target temperature of the
hot roller during copying with
OHP/thick paper in full color
mode.
150
130 to 170 (
°
C)
1 105 5 Set Hot Rllr.Tmp.Thin:FC
Sets the target temperature of the
hot roller during copying with thin
paper in full color mode.
150
130 to 170 (
°
C)
1 105 6 Set Hot Rllr.Tmp.Nrml:SC
Sets the target temperature of the
hot roller during copying with
normal paper in single color
mode.
140
130 to 170 (
°
C)
1 105 7 Set Hot Rllr.Tmp.OHP:SC
Sets the target temperature of the
hot roller during copying with
OHP/thick paper in single color
mode.
140
130 to 170 (
°
C)
1 105 8 Set Hot Rllr.Tmp.Thin:SC
Sets the target temperature of the
hot roller during copying with thin
paper in single color mode.
140
130 to 170 (
°
C)
1 105 9 Set Pressure Roller Temp
Sets the target temperature of the
pressure roller.
150
130 to 170 (
°
C)
If the first side of a duplex
copy is sticking to the
pressure roller, lower the
temperature.
Do not input a value higher
than 167
°
C. The thermofuse
opens at 167
°
C.
PAPER FEED/TRANSPORT/FUSING
SM APPENDIX 11-21 A166/A187/A189
CÓPIA NÃO CONTROLADA