Service manual
4787
500
400
1000
1181
4895
371
4200
229
1952
1238
210
4524
4629
4686
5190
1190
8562
4733
5305
971
1495
1467
1114
4733
18495
10219
10162
10019
9257
Half-speed
4000
Half-speed
Half-speed
561
Copy Mode: Half-speed (OHP/Thick)
Color Mode: Black
Size: A3
Copy Volume: 1 sheet
Magnification:100%
Note: 1. Time units are in [ms].
2. Timing is accurate within 20 [ms].
3. The revolver unit does not rotate while the drum motor or the development roller rotate at half speed.
4. The time between the belt H.P. detection and FGATE (400 [ms]) depends on the scanner registration adjustment.
1. Start Key
2. Drum Motor
3. Main Motor
4. Belt H.P. Detection
5. Scanner Lamp
6. Scanner Motor
7. FGATE
8. QL
9. Charge corona
10. Development Bias DC
11. Development Bias AC
12. Development Motor
13. Toner Supply Motor
14. ID Sensor Pattern
Writing
15. PTL
16. Toner Supply Motor
Solenoid
17. Revolver Motor
18. Belt Transfer Charge
19. Paper Transfer
Charge
20. Negative Voltage
Relay
21. Negative Voltage
(Paper-Transfer)
22. Transfer Belt Cleaning
Solenoid
23. Registration Clutch
TIMING CHART 10 [Half-speed/Bk/A3]
SM APPENDIX 11-10 A166/A187/A189
CÓPIA NÃO CONTROLADA