Service manual
2-1. Potential sensor/ID sensor check
Using a digital oscilloscope, check the waveforms at the following terminals.
If the waveforms are flat, the sensor is broken.
• Potential sensor (V-SEN)
TP213 on the main control board and GND (Ground)
• ID Sensor (P-SEN)
TP217 on the main control board and GND (Ground)
After connecting the digital oscilloscope, reassemble the machine, perform
the forced process control self check (SP3-126), and check the waveforms
while the self check is running.
If the shapes are similar to those shown in the diagram, there is no problem.
(The exact shapes and amplitudes of the peaks depends on the machine’s
condition and environmental circumstances.)
PRIN
ROM
ROM
SCSI CN
SCSI CN
GND
DIP
SW
P-SEN
TP217
V-SEN
TP213
GND
FUSE
Front
for YMC
Potential
sensor
ID sensor
for Bk
ID sensor
Potential
sensor
HOW TO DETERMINE IF THE POTENTIAL SENSOR OR ID SENSOR IS DEFECTIVE
A166/A187/A189 6-36 SM