Service manual

Procedure
CAUTION
Before checking the resistance or potential of the sensors, make sure
to unplug the power cord.
1-1. Measure the resistance between the drum surface and drum shaft.
Normal resistance*: 0.3
~ 0.5
Remove the charge corona unit. Then, contact the edge of the drum surface
through the space where the charge corona unit was.
1-2. Check the resistance between the drum shaft and the grounding
wire terminal.
Remove the fly wheel securing screw and the fly wheel.
Measure the resistance between the shaft and the grounding wire
terminal.
Normal condition*: 4
~ 5
.
(This value includes the bearing resistance)
* : These values come from a test machine, therefore the values are just
reference data and might not suit your machine.
Trouble-
shooting
HOW TO DETERMINE IF THE POTENTIAL SENSOR OR ID SENSOR IS DEFECTIVE
SM 6-35 A166/A187/A189