Service manual
Procedure
CAUTION
Before checking the resistance or potential of the sensors, make sure
to unplug the power cord.
1-1. Measure the resistance between the drum surface and drum shaft.
Normal resistance*: 0.3
Ω
~ 0.5
Ω
Remove the charge corona unit. Then, contact the edge of the drum surface
through the space where the charge corona unit was.
1-2. Check the resistance between the drum shaft and the grounding
wire terminal.
• Remove the fly wheel securing screw and the fly wheel.
• Measure the resistance between the shaft and the grounding wire
terminal.
Normal condition*: 4
Ω
~ 5
Ω
.
(This value includes the bearing resistance)
* : These values come from a test machine, therefore the values are just
reference data and might not suit your machine.
Trouble-
shooting
HOW TO DETERMINE IF THE POTENTIAL SENSOR OR ID SENSOR IS DEFECTIVE
SM 6-35 A166/A187/A189
CÓPIA NÃO CONTROLADA