Service manual

SC990: I/O control board 1 abnormal
Type: 2
- Description -
This SC is displayed when a serial/parallel I/O error is detected in the
I/O control board 1 for a successive five times.
- Detection Timing -
Always
- Possible Causes -
I/O control board 1
Corona unit setting error
Connector/harness
Main control board
SP-Log: 7-402-9
SC991: I/O control board 2 abnormal
Type: 2
- Description -
This SC is displayed when a serial/parallel I/O error is detected in the
I/O control board 2 for a successive five times.
- Detection Timing -
Always
- Possible Causes -
I/O control board 2
Corona unit setting error
Connector/harness
Main control board
SP-Log: 7-402-9