Service manual
SC791: Projector lamp does not go off
Type: 4
- Description -
The projector diagnostics notify the scanner IPU board when the
projector lamp does not go off although the OFF command is issued.
Then the scanner IPU board notifies the SCU of it.
- Detection Timing -
When the projector is stopped
- Possible Causes -
• Projector control board
SP-Log: 7-402-7
SC792: Projector lamp overheat
Type: 4
- Description -
The projector diagnostics notify the scanner IPU board that the
projector lamp has overheated. Then the scanner IPU board notifies
the SCU of it.
- Detection Timing -
When the projector is active
- Possible Causes -
• Projector control board
SP-Log: 7-402-7
SC900: Main counter disabled
Type: 2
- Description -
Communication error between the main counter and main control board
- Detection Timing -
When counter information is uploaded or downloaded
- Possible Causes -
• Main counter
• Main control board
• SCU harness
SP-Log: 7-402-9
SERVICE CALL CONDITIONS
A166/A187/A189 6-30 SM