11. Disconnect the fusing thermofuse connector [A].
12. Disconnect the fusing thermistor connector [B].
13. Disconnect the connector [C] at the rear of the fusing lamp.
14. Disconnect the connector [D] at the rear of the pressure roller lamp.
15. Remove the fusing unit connector bracket [E] (2 screws and 1 E-ring).
16. Remove the fusing unit upper assembly [F] and the oil sump [G] (7
screws).
NOTE: Ensure that the fusing lamp harness is not caught when removing
the fusing unit upper assembly. A strong force erted on the harness
may damage the fusing lamp.
[E]
[C]
[D]
[B]
[A]
[F]
[G]