Service manual

8.3 BY-PASS FEED UNIT REPLACEMENT
1. Remove the right cover, the right rear cover, and the right front cover (see
procedure 1.7).
2. Remove the by-pass feed table (see procedure 8.1).
3. Remove the developer collection bottle/supply funnel ass’y [A] from its
storage position (1 screw).
4. Open the vertical transport door [B].
5. To remove the by-pass feed unit [C]
1) Remove the 2 connectors and 2 screws.
2) Carefully remove the front end [D] of the by-pass feed unit and slowly
pull it free.
3) Gently twist the by-pass feed unit and completely remove it.
NOTE: While removing the by-pass feed unit, take care not to damage the
gears at the rear end of the unit.
[A]
[B]
[C]
[D]