6.2 PROCESS CONTROL SELF-CHECK
After replacing developer, the development unit (containing new black, cyan,
magenta and yellow developers) or the photoconductor drum, do the SP
modes listed in the SP Modes After Replacing and Cleaning table in section
4, Service Tables.
CAUTION
While performing the process control self-check, do not touch the
drum shaft, knob screw, or flywheel. A high voltage of -800V is
applied during potential sensor correction. Therefore, there is a risk of
severe electric shock if these parts are touched.
NOTE: When agitating the developers, use the SP mode that suits on the
color of the developers that were replaced, as follows:
1) When all developers (black, cyan, magenta, and yellow) were
replaced:
SP2-225-5 (Developer Aging: All Colors)
2) When only black developer was replaced:
SP2-225-1 (Developer Aging: Bk)
3) When cyan, magenta, and yellow developers were replaced:
SP2-225-6 (Developer Aging: C, M, Y)
4) When only cyan developer was replaced:
SP2-225-2 (Developer Aging: C)
5) When only magenta developer was replaced:
SP2-225-3 (Developer Aging: M)
6) When only yellow developer was replaced:
SP2-225-4 (Developer Aging: Y)
Rev. 11/96
DEVELOPMENT UNIT
A166/A187/A189 5-48 SM
CÓPIA NÃO CONTROLADA