77. Perform the ACC (Auto Color Calibration) procedure in section 5 of the
service manual.
78. Input the current date and time with SP5-302-1.
EXAMPLE: Date Format: YYYYMMDDhhmmd
1996031200301
1996 = year
03 = month
12 = day of month
00 = hour (00 - 23)
30 = minute (00 - 59)
1 = day of week (Sun. - Sat. = 0-6)
79. Reset the main counter and the backup counter with the following
procedure.
(1) Enter SP mode.
(2) Enter SP7-914-1 and input the setting "1". Press the R/# key. This will
reset the main counter, the back up counter and the CE counter.
NOTE: Resetting all three of these counters with SP7-914-1 can be done
only at copier installation or at replacement of the RAM on the
SCU board.
80. A189 copier only:
(1) Enter SP mode.
(2) Enter SP 5-9-1 and input the following setting in accordance with the
language which should be displayed on the operation panel.
1: English (NA) 2: English (EU) 3: German (EU)
4: French (EU) 5: French (NA) 6: Italian (EU)
7: Spanish (EU) 8: Danish (EU) 9: Norwegian (EU)
10: Swedish (EU) 11: Dutch (EU) 12: Portuguese (EU)
13: Czech (EU) 14: Spanish (NA) 15: Portuguese (NA)
NOTE: 1) When the setting is NA, the original size detection is set to LT/DLT
version.
2) When the setting is EU, the original size detection is set to A4/A3
version.
Installation
Procedure
COPIER INSTALLATION
SM 3-35 A166/A187/A189