Service manual

NOTE: 1. The covers must be closed before turning on the main switch
because the initial process control self check must be performed
(this takes about 5 minutes).
2. Displays the process control self check result by a code number.
3. This step removes the residual voltage on the drum left by the initial
process control self check.
4. SP2-225-5 develops the pattern on the drum (Bk, C,M,Y)
necessary for toner replacement. It replaces the old toner in the
developer and then agitates the developer and toner. It also will
correct a toner end or toner near end condition.
This SP takes between 30 and 55 minutes.
Check the amount of toner remaining before developer agitation. If
there is not much, replace the toner cartridge to prevent an
agitation error.
Installation
Procedure
COPIER INSTALLATION
SM 3-33 A166/A187/A189
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA