Service manual

Result ?
SP3-975
(Displays the Result
2
)
SP3-126
(Forced Process Control
Self Check)
Wait 10
minutes
3
Is this the third
Bad Result (80, 81,
85, 90, 91, 92, 93, or
95) in a row?
Main SW
Off
Fix the problem by
following the
process control
error code table in
section 2. (1.3.14).
Main SW
On
1
YES
Developer Agitation for All Colors
Result = 80, 81
90, 91, 92, 93,
or 95
(Bad Result)
Result = 01, 94, 96,
or 99 (Good Result)
NO
Main SW On
1
Check the result of
Developer Agitation
(SP3-964).
End
Result = 1
(Good
Result)
See the developer agitation
error code table in section 2
(1.4.6) for detail.
Result =
70 - 79
(Bad
Result)
Perform SP2-225-5
once
4
.
Enter the SP mode, as follows:
1. Press the Clear Modes key.
2. Enter "107" with the no. keys.
3. Hold down the Clear/Stop key
for more than 3 seconds.for more than 3 seconds.
Start
NOTE: Refer to Table 1.3.14 in the
"Detailed Section Descriptions"
section of this manual.
COPIER INSTALLATION
A166/A187/A189 3-32 SM