Service manual
45. Remove the charge corona unit [A] (1 screw).
46. Remove the following parts in the following order:
➀
Drum stay screw [B]
➁
ID sensor shield plate screw [C].
➂
Knob screw [D].
NOTE: When removing the drum stay, be sure to remove the drum stay
screw before the knob screw. If the knob screw is removed first,
the drum stay may be bent by the pressure of the drum securing
spring.
47. Remove the drum stay [E] while pushing the ID sensor shield plate [F]
towards the outside.
– For 220/240 V machine only –
•
Remove the LD shield plate [X] (3 screws).
48. Remove the drum securing spring [G] and disconnect the 3 connectors
[I]. Then remove the drum unit by pulling the grip [H] (3 connectors).
[E]
[D]
[A]
[B]
[C]
[F]
[C]
[D]
[X]
[G]
[H]
[I]
Installation
Procedure
COPIER INSTALLATION
SM 3-23 A166/A187/A189
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA