TABLE 1: Ricoh, Savin, Lanier, Gestetner
6-Price Machine Harness (609348-001) For 5596 Series
Price BK/W or Color Size
1 BK/W (LT) 11”x 8 1/2”
2 BK/W (LG) 8 1/2”x 14”
3 BK/W (DLT) 11”x 17”
4 N/A N/A
5 N/A N/A
6 N/A N/A
7 N/A N/A
8 N/A N/A
9 Color (LT) 11”x 8 1/2”
10 Color (LG) 8 1/2”x 14”
11 Color (DLT) 11”x 17”
12 N/A N/A
13 N/A N/A
14 N/A N/A
15 N/A N/A
16 N/A N/A
TIMING HELP
Please refer to your VENDAPIN, LLC user manual for the proper procedure to change the timing settings described below.
DEFINITIONS
Sense Time – The length of pulse the VENDAPIN unit will recognize. Sense time MUST be set shorter than the pulse length.
Example: The pulse length is 120ms, the sense time is set to 130ms. The VENDAPIN unit will not recognize the pulse
because the sense time is longer than the pulse.
Blind time – The length of time the VENDAPIN unit will ignore any input pulses AFTER it is finished sensing the debit pulse.
Reset delay time – The amount of time from the end of the blind time to reset, or disable, the copier.