Complete the following steps to restore the controller to the default network
settings.
1. Move the IP RESET switch to the ON position.
2. Push the RESET button to cycle power to the controller. The STATUS
LED flashes once, indicating that the controller IP address is
unconfigured.
3. Move the IP RESET switch to the OFF position.
You can reconfigure the settings in MAX from a computer on the same
subnet. Refer to the Measurement & Automation Explorer Help for more
information about configuring the controller settings.
Note If the controller is restored to the factory network settings, the LabVIEW run-time
engine does not load. You must reconfigure the network settings and restart the controller
for the LabVIEW run-time engine to load.
Specifications
The following specifications are typical for the entire operating
temperature range, –20 to 55 °C, unless otherwise noted.
Network
Network interface
Ethernet port 1 ................................ 10BaseT, 100BaseTX, and
1000BaseTX Ethernet
Ethernet port 2 ................................ 10BaseT and 100BaseTX
Ethernet
Compatibility ......................................... IEEE 802.3
Communication rates
Ethernet port 1 ................................ 10 Mbps, 100 Mbps, and
1000 Mbps, auto-negotiated
Ethernet port 2 ................................ 10 Mbps, 100 Mbps,
auto-negotiated
Maximum cabling distance .................... 100 m/segment
RS-232 DTE Serial Port
Baud rate ................................................ 300–230,400 bps
Data bits ................................................. 5, 6, 7, 8
Stop bits.................................................. 1, 1.5, 2