RW-470 Technical Manual Final Version
Trademarks Adobe , Acrobat , PostScript and PostScript 3TM are registered trademarks of Adobe Systems Incorporated. Apple, Macintosh, Mac and TrueType are registered trademarks of Apple Computer, Incorporated. AutoCAD and DWG are registered trademarks of Autodesk, Inc. HPGL, HPGL/2 and HP-RTL are registered trademarks of Hewlett-Packard Company. Ethernet is a registered trademark of Xerox Corporation.
CONTENTS Contents Technical Manual................................................................4 Package list ........................................................................4 System requirements..........................................................5 Memory requirements .................................................................6 Printer Controller RW-470 ..................................................7 Technical Data .................................................................
TECHNICAL MANUAL Technical Manual This technical manual explains some problem solutions, provides you with technical data and background information for the RW-470 plot management system programs. We wish you every success in working with the RW-470 programs. Package list The delivery includes • Installation sheet, • the RW-470 Controller, • one CD with Software and PDF-Manuals, • one 3,5 inch-disc with RSP-License files.
SYSTEM REQUIREMENTS System requirements Please read through the following recommendations carefully. They can be very helpful in finding the optimum hardware for your needs. • Operating system: Microsoft Windows 2000 Professional with ServicePack 1 or higher • Processor: Pentium III, 800 Mhz or higher. • PCI Bus: The PCI bus system must meet up-to-date standards (PCI 2.0 or higher – 3.3 V or 5 V autoadaptive, maximum load 5 A).
SYSTEM REQUIREMENTS • Monitor: At least 1024 x 768 pixels resolution Memory requirements In the following chart the possible sizes of plots were calculated. The sizes of plots depend on the size of the main memory. In the first chart you can see the results for documents with an average complexity and in the second the results for documents with high complexity. Further assumption are: • All calculations are based on a transportation speed of 90 mm/s.
PRINTER CONTROLLER RW-470 Printer Controller RW-470 The RW-470 Software works only, if you have installed an controller. You have to install the Printer Controller RW-470 and the appropriate software. In the next chart the technical data are listed. In the following chapter the installation of the kernel driver is explained. Technical Data Item PCI style Bus-Width max. PCI bus clock physical dimension PCB dimension power supply max power consumption max memory on board Connection to copier max.
PRINTER CONTROLLER RW-470 Changes to the Controller RW-470 are possible and the manufacturer does provide separate information of them. The technical specifications comply with Installing the Controller into your PC Note: The Printer Controller RW-470 is – like all other high integrated circuits – sensitive to electrostatic charge. Therefore, remove the controller carefully from the shipping container and do only touch it at the side or at the bracket.
PRINTER CONTROLLER RW-470 If the kernel driver (device driver) „Printer Controller RW470Drv“ is not running: Start event-viewer START->Programs>Administration->Eventviewer and find out reason for failure. Only if the PRINTER CONTROLLER RW-470DRV Driver is running, you can use the controller.
FREQUENTLY ASKED QUESTIONS Frequently asked questions This chapter contains an overview of which commonly asked questions can arise when working with RW-470 PLOTBASE and how you can solve them. See also the explanations about “error messages” in the RW-470 PLOTBASE manual. The topics are arranged in groups under terms, which are sorted alphabetically: • Jobs are not printed, indication „Please wait“ in the status window On the display of the plotter the interrupt button was activated.
FREQUENTLY ASKED QUESTIONS d. Carry out a “Test plot“, to check correct function of the plotter. For that select “Job – Test Print”. e. Check whether the “Interrupt“ switch at the scanner display has been activated. Deactivate it. f. Check the connection cable between the scanner and server. 2. File error a. If a file certain file type (PDF, CGM, or similar.) cannot be printed, you must first acquire the relevant licenses for these optional file formats and install a license file. b.
FREQUENTLY ASKED QUESTIONS format. Either you enter the gray scale for each individual color in percent or you set pens the pens to “Gray“ and enter the required percentage value. • Lines are not visible If the file to be plotted is in a HPGL or Calcomp format, the color can be set too light or the pen widths are too small. • Printout plotted on an unexpected medium The plotter can sometimes print on another roll that you expected, although you entered the default values correctly.
FREQUENTLY ASKED QUESTIONS 2. Note the minimum pen widths when scaling. C.f. Pen widths. • Pen widths Ensure that you observe the minimum pen widths for vector images. Scaling a drawing smaller and scaling the pen widths too can lead to loss quality and information in the printout.
OVERVIEW OF THE FILE FORMATS Overview of the file formats In the following chart all file formats are listed. The standard formats are listed in the first chart and the optional formats are listed in the second chart. In the column „Read“ you can see, which file format can be opened and read. In column „Write“ you can get the information which file formats can be created after scanning or editing and which not.
OVERVIEW OF THE FILE FORMATS CALS CIT HPGL, HPGL/2 HP-RTL DODISS, Department of Defense Index of Specifications and Standards MIL-STD1840B b/w MIL-STD28002A b/w „SDN 84-007 / Version 3.2.
OVERVIEW OF THE FILE FORMATS The following file formats are optional. You can use the DWG format only, if you have installed an AutoCAD program on your PC. DWG RW470PS CGM 16 Autodesc “RW-470PS Level III Compatible Option” „NIST CGM ATA, Release 2.
ADDITIONAL FONT PATHS Additional font paths To enter additional font paths and thus additional fonts proceed (if you are the administrator) as follows: 1. Open the registry editor. Select the following file: \\HKEY_LOCAL_MACHINE\SOFTWARE\RW470\PLOTBASE\PLOTSERVER\3.0\FORMATS\RW-470PS EPS\ FontPath Open an edit dialog by double clicking on the file name. / 2. The existing entry “.;.\Font“ of the above figure is based on the following syntax rules: • .
PRODUCING SSL FILES Producing SSL files The structure and commands of the SSL files are described in this chapter. You can use the SSL commands to configure the print job yourself. There are three classes of SSL commands: Structured commands, SSL commands and parameters. This description explains the structured commands first, there then follows an alphabetical list of the SSL commands with the corresponding parameters. Structured commands A job begins with BeginJob and ends with EndJob.
PRODUCING SSL FILES EndOutput EndJob Example 2: BeginJob Copyright CreationAppl Comment JobName UserName Account Notes Distribution Copies JobCollate JobFlagSheet ... Floorplan "1998 Schmidt" "BSP R1.01" Job Settings "TEST_1" "ROS" "MAGIC“ "TEST EXAMPLE" "TO: KSC, JGE " 2 on Job ; Input Defaults OrigDirectory HpglPens FileEmulation .... "C:\\TEST" off auto ; Output Defaults Stamp + Zoom Rotate ... text "COMPANY STAMP" position bottomleft coordinate 100 100 100. 100.
PRODUCING SSL FILES BeginOutput ... Stamp Name ... off "PLOT.001" EndOutput EndJob SSL commands For each SSL command you will find descriptions, which are labeled with the abbreviations SC, C, SY, D. They mean the following: • SC (Scope): This describes where the command can be placed. JOB is in the area between BeginJob and the first BeginOutput. Here there are commands, which always affect a set as a whole, e.g. Customer or e-mail, and the defaults for the SSL commands, which concern the entries.
PRODUCING SSL FILES Any number of symbols (including none) by round brackets with asterisk: ( )* More than one symbol with round brackets with Plus : ( )+ One or no symbols with round brackets with question mark: ( )? A normal arithmetic bracket is also round: ( a | b ) D (Default): This is where the program defaults are if there is no SSL ( and no default.ssl ). - • The SSL commands are listed in the following.
PRODUCING SSL FILES C = any text, which is stored in the archive, to label the drawing. Any alphanumeric string is valid.
PRODUCING SSL FILES = ( number ( | - | all ) )+ = width color saturation ( pattern )? = circle | random D = off Comment or ‘;’ ■☺ SC = JOB, ENTRY C = any comment up to the end of the row is ignored and is lost when processed by the program. See also Note. SY = Comment or ; D =– Confirmation SC = JOB C = When switched on, stops the processing after the first plot.
PRODUCING SSL FILES D =– CostCenter ■ SC = JOB C = Text, which identifies the account. Interesting for an accounting module. SY = CostCenter D =– CreationAppl ■ SC = JOB C = Text, which identifies the generating applications. SY = CreationAppl D =– Customer ■☺ SC = JOB C = Text, which identifies the job’s customers. SY = Customer D =– CutMethod ■☺ SC = JOB, ENTRY C = standard : Standard formats are cut. synchro : The cuts match the plot.
PRODUCING SSL FILES SY = DeleteAfterPlot ( on | off ) D = off Directory ■ SC = ENTRY C = The directory, in which the plot file is, absolute paths are not currently possible, therefore, SSLs can not be simply copied with your image directories. SY = Directory D =– Distribution ■☺ SC = JOB C = Distribution, which can be printed on the JobFlagSheet. SY = Distribution D =– EarliestPlotTime SC = JOB C = Earliest time at which the set is to be printed.
PRODUCING SSL FILES C = Gives the file format of the plot file, if auto, the plot software decides which format is available. SY = FileEmulation ( auto | CalComp | CALS | HPGL | HPGL2 | PCX | TIFF | RLC | MTF ) D = auto HeaderPosition ■☺ SC = JOB, ENTRY C = Gives where the drawing header is located.
PRODUCING SSL FILES green, 2 = blue dithermode: for HPGL / RTL SY = Hpgl ( )+ = ( filepensize ( on | off ) ) | ( filepcolor ( on | off ) ) | ( penscale ( on | off ) ) | ( minwidth ) | ( maxwidth ) | ( stepsize ) | ( patterntype ( random | circle | loadablepattern | ordereddither ) ) | ( ignorepensize ( on | off ) ) | ( bicolorrgb ( 0 | 1 | 2 ) ) | ( dithermode ( ordereddither | errordiffusion ) ) D = filepensize on, filepencolor on, penscale off, minwi
PRODUCING SSL FILES C = inverts the plot SY = Invert ( on | off ) D = off JobCollate ■☺ SC = JOB C = on: Sorts the plots in sets ( 123123); off: Prints the same plots one after the other ( 112233 ) only effective if SetCopies > 1: SY = JobCollate ( on | off ) D = on JobFlagsheet ■☺ SC = JOB C = The flagsheet is an information sheet, which can be printed off for unsorted issue per set or for sorted issue per set copy.
PRODUCING SSL FILES SY = JobName D =– JobPlotter ■ SC = JOB C = Controls the printout on a certain plotter, if several plotters are connected to the plot server ( PLOTSERVER ) SY = JobPlotter ( auto | ) D = auto JobPriority ■ SC = JOB C = Priority of the jobs in the queue SY = JobPriority ( high | normal | low | wait | immediate ) D = normal Margin ■☺ SC = JOB, ENTRY C = Adds a white margin to the drawing.
PRODUCING SSL FILES D = exact MediaPosition ■ SC = JOB, ENTRY C = Position of the plot on the paper. SY = MediaPosition ( auto | ) = ul | upperleft | uc | uppercenter | ur | upperright | lc | leftcenter | cc | centercenter | rc | rightcenter | bl | bottomleft | bc | bottomcenter | br | bottomright D = ul MediaType ■☺ SC = JOB, ENTRY C = Medium, on which the plot is printed.
PRODUCING SSL FILES Notes ■☺ SC = JOB, ENTRY C = Comment on job / Plot, is retained during processing SY = Notes D =– OnError SC = JOB C = Reaction to errors; abort = abort set and continue with the next set; continue = continue with the next entry; query = display message and hold the plot until operator intercedes. SY = OnError ( abort | continue | query ) D = continue OperatorMode SC = JOB C = on: The plot software calls the operator when plotting the job.
PRODUCING SSL FILES SY = OrigName D =– OutputBin ■☺ This is for the Input tray. SC = JOB, ENTRY C = Roll to be plotted from. SY = OutputBin ( auto | manual | Bin ) D = auto OutputSize ■☺ SC = JOB, ENTRY C = choice of the paper format. window : customer-specific format, image is distorted. proportional : customer-specific format, image proportions are retained. auto: the zoom setting determines the size of the printout.
PRODUCING SSL FILES if e.g. only one tray is accessible.
PRODUCING SSL FILES D =– Rotate ■ SC = JOB, ENTRY C = Rotate the image SY = Rotate ( auto | 0 | 90 | 180 | 270 ) D = auto SecurityPrint ■ This is for “Locked Print”. SC = JOB C = The set remains in the queue and is not plotted, until a password is entered. After the password is entered the set is given the priority immediate and DeleteAfterPlot. The set cannot be edited without a password.
PRODUCING SSL FILES Name and path of the image. bmporientation : where is the image with relation to the stamp text. bmpdistance : Distance between stamp text – stamp image. framesize : Thickness of the frame surrounding the stamp. frametextdistance : Distance of the frame from the text. mirror, rotate : Mirror and rotate ( 0 – 359°) the stamp. color : Gray scale value. overlay : type of cover if the stamp covers drawing contents. numbering : Start number for numbering the plots for Copies > 1.
PRODUCING SSL FILES SC = JOB C = The first copy of the set is plotted, then an operator input is waited for, to say whether the other copies are also to be printed. SY = TrialPrint ( on | off ) D = off Units ■ SC = JOB C = Unit of the job size information. SY = Unit ( cm | mm | inch | ( points | pt | pixel ) ) D = mm UserName ■☺ SC = JOB C = User name to be able to assign the jobs. SY = UserName D =– Zoom ■☺ SC = JOB, ENTRY C SY 36 = Scaling factor.
PRODUCING CFG FILES Producing CFG files This chapter explains the CFG file structure and commands. CFG files are usually produced normally automatically and are sent with the corresponding drawing files to the RW-470 PLOTBASE. They contain the settings for the print off. You can use the CFG commands explained in this chapter to produce your own CFG file. To do this, you only need a simple text editor. Save the file when ready as .cfg. The CFG file and the drawing file must have the same name.
PRODUCING CFG FILES A CFG file contains the following entries: ENTRY INPUTBIN CUT COPYCOUNT ROTATE INVERT MIRROR FOLD SCALEMODE SCALEAUX1 SCALEAUX2 MEDIUM PRIORITY ENTRY USER 38 RW-470 VALUES AUTO 1..n ON OFF EXAMPLE AUTO EXPLANATION Input tray ON 1..999 AUTO 0 90 180 270 ON OFF OFF X Y XY OFF 1..xx ORIGINAL PERCENT FORMAT WINDOW ORIGINAL: not used PERCENT Percent times 100 FORMAT: DIN A0..
PRODUCING CFG FILES ORIGINALFILE CALCOMP PEN01 CALCOMP PEN02..PEN16 STEPSPERCM CCCHECK SMITH C:\DEMO\ LAND.PLT Pen width of the pen 250 01 in 1/1000 mm ... 0..32Pixel 250 800 OFF CCSYNC01 1..9999 ON OFF 2 CCSYNC02 0 CCENDCHAR 3 HPGL / HPGL2 PEN000 0..9.99 mm, 0.36,WHITE HPGL / HPGL2 PEN001 HPGL / HPGL2 PEN002..PEN255 RED 0..9.99 mm, 0..9.99 mm, BLACK WHITE GRAY dto dto dto dto dto dto dto dto dto dto dto ON OFF 0.
PRODUCING CFG FILES BORDERTOP BORDERBOTTOM BORDERLEFT BORDERRIGHT 40 RW-470 0..xxxx 0..xxxx 0..xxxx 0..
HPGL/2 COMMANDS AND PENS HPGL/2 commands and pens In this chapter we have listed all the HPGL/2 commands that the program fully or partially supports: + = command is fully supported ~ = command is partially supported • Configuration and status group: DF IN IP IR IW PG RO SC = = = = = = = = + + + + + + + + • Vector Group: AA AR AT CI PA PD PE PR PU RT = = = = = = = = = = + + + + + + + + + + • Polygon Group: EA EP ER EW FP PM RA = = = = = = = + + + + + + + RW-470 41
HPGL/2 COMMANDS AND PENS RR WG = = + + • Line and Fill Attributes Group: AC FT LA LT PW RF SM SP UL WU = = = = = = = = = = + + ~ + + + + + + + • Character Group: AD CP DI DR DT DV ES LB LO SA SD SI SL SR SS TD = = = = = = = = = = = = = = = = ~ + + + + + + + + + ~ + + + + + • Technical Graphics Extensions: BP CT DL MC PS 42 = = = = = RW-470 + + + + +
HPGL/2 COMMANDS AND PENS • Palette Extension: CR NP PC SV TR = = = = = + + + + + • Dual-Context Extension: No commands are supported • Digitizing Extension: No commands are supported • Default values for HPGL pens: All 256 HPGL pens have the pen thickness 0.35 mm as their default value.
CALCOMP COMMANDS AND PENS Calcomp commands and pens In this chapter we have listed all the Calcomp commands and their implementation status in RW-470 PLOTBASE. The standard pen widths for the 16 Calcomp pens are given at the end of the chapter.
CALCOMP COMMANDS AND PENS • Symbols Commands: font selection symbol string count plotter symbol scaling controller symbol scaling symbol characteristics extended characters select symbol set 0-4 plotting symbol from selected symbol set user defined symbol erase user symbol set + [not all symbols] + + + + + + + + + • Circles Commands: chordal tolerance circle command for circles circle command for arcs + + + • Dashlines Commands: dash bypass dashline + + • Additional Commands: no operation pass throug
CALCOMP COMMANDS AND PENS Pen 46 Pen width in mm Pen width in pixels 4 0.25 4 5 0.32 5 6 0.38 6 7 0.44 7 8 0.51 8 9 0.57 9 10 0.64 10 11 0.70 11 12 0.76 12 13 0.83 13 14 0.89 14 15 0.95 15 16 1.
REGISTRY ENTRIES Registry entries In the registry editor you can alter several sub-trees for RW-470 PLOTBASE. The following lists a selection of entries from the registry editor, which can be entered during the installation of RW-470 PLOTBASE and can then be changed by you. However, not all the entries have been listed, as either some of them should not be changed by you or they occur several times with respect to their meaning. Key name: SOFTWARE\RW-470\PLOTBASE\PLOTSERVER\3.
REGISTRY ENTRIES Type:REG_SZ Data: 00000000 [Comment: 0: At the end of the roll only use identical roll, otherwise wait,1: At end of roll only use compatible roll, otherwise wait}] Name: SpoolTimeout Type:REG_DWORD Data: 00000000 [Comment: Timeout for incomplete jobs in seconds] Name: Dao Type:STRING Data: C:\RW-470\PLOTBASE\PROGRAM\CBDB.
REGISTRY ENTRIES Data: 00000000 [Comment: Percentage, how much HDD capacity can be used by the plot server] Name: ErrorHandling Type:REG_DWORD Data: 00000000 [Comment: Strategy for errors that occur: 0: In case of error do not plot any further jobs,1: In case of error plot next jobs] Name: JobHistoryDeleteCapacity Type:REG_DWORD Data: 00000001 [Comment: Percentage HDD capacity, if the given limiting value is exceed, jobs that have already been plotted are deleted until the value is less than the limiting v
REGISTRY ENTRIES Name: LogFileName Type:STRING Data: %temp\\COPYBASELoggingPlot [Comment: Path + Name of the log file, if switched on (for error detection)] Name: Logging Type:REG_DWORD Data: 00000000 [Comment: logging on/ off] Name: Server Type:STRING Data: RW-470 PLOTBASE - Server [Comment: Name of the plot server] Name: ServerExe Type:STRING Data: C:\RW-470\PLOTBASE\PROGRAM\PbDbRu.
REGISTRY ENTRIES Type:REG_DWORD Data: 00000000 [Comment: FilePrint on/ off- if on, then plot to file] Name: View Type:STRING Data: PLOTBASE - UI [Comment: Name of the plot server controller] Name: ViewOn Type:REG_DWORD Data: 00000001 [Comment: Fileview on/ off] Name: DBOn Type:REG_DWORD Data: 00000001 [Comment: internal value for the start of the controller and the server] Name: SslOn Type:REG_DWORD Data: 00000000 [Comment: Reader on/ off] Name: SignalLightsOn Type:REG_DWORD Data: 00000000 [Comment: Signal
REGISTRY ENTRIES Name: ResponsePath Type:STRING Data: C:\SPOOL\response [Comment: Path for Response file (uses RW-470 PLOTCLIENT WEB)] Name: FilePrintDestination Type:STRING Data: f:\\fileprint [Comment: if UseFilePrint = 1, directory, where the FilePrint is to be written to] Name: Logging Type:REG_DWORD Data: 00000000 [Comment: 1: If logging switched on, 0: Logging switched off] Name: LogLevel Type:REG_DWORD Data: 00000000 [Comment: If logging switched on: 1: error message, 2: Warnings, 3: Traces, 4: Reg/
REGISTRY ENTRIES Type:REG_DWORD Data: 00000000 [Comment: Direction of the drawing rotation, clockwise or anticlockwise] Name: SizeTolerance [mm] Type:REG_DWORD Data: 00000002 [Comment: If the printout is this value larger than the roll available, then nevertheless plotted] Key name:SOFTWARE\ RW-470\PLOTBASE \ PLOTSERVER\ 3.0\PBWnd These values give the colors of the jobs in the job list. The RGB colors are given in hexadecimal figures. The last six figures are used for this.
REGISTRY ENTRIES Name: ColorSecurityPlot Type:REG_DWORD Data: 00ff8000 [Comment: Color for “Password“ status] Name: ColorTrialPrint Type:REG_DWORD Data: 00ff8000 [Comment: Color for “Test Print“ status] Key name: SOFTWARE\RW-470\PLOTBASE\PLOTSERVER\3.0\ PBReader\Config\Registration Name: ConfigCount Type:REG_DWORD Data: 00000002 [Comment: Number of spool paths] Key name:SOFTWARE\RW-470\PLOTBASE\PLOTSERVER\3.
REGISTRY ENTRIES Name: ConfigParserTime Type:REG_DWORD Data: 00001388h [Comment: Timeout for the parser] Name: ConfigReadyFile Type:REG_DWORD Data: 00000000 [Comment: Activate Ready File Action; 0: False, 1:True] Name: ConfigParserOn Type:REG_DWORD Data: 00000001 [Comment: Activate reader; 0: False, 1:True] Name: ConfigDefSSLFile Type: REG_SZ Data: default.ssl [Comment: Name of the default SSL file] Name: ConfigDefCFGFile Type: REG_SZ Data: default.
REGISTRY ENTRIES [Comment: Reference to the reader types] Name: ConfigWindowName Type:REG_DWORD Data: SSL [Comment: Name of the input queue] Name: ConfigParserPath Type: REG_SZ Data: F:\\SPOOL\\SSL [Comment: Spool path] Name: ConfigParserTime Type:REG_DWORD Data: 00001388h [Comment: Timeout for the parser] Name: ConfigReadyFile Type:REG_DWORD Data: 00000000 [Comment: Activate Ready File Action; 0: False, 1:True] Name: ConfigParserOn Type:REG_DWORD Data: 00000001 [Comment: Activate reader; 0: False, 1:True]
REGISTRY ENTRIES Key name: SOFTWARE\RW-470\PLOTBASE\ PLOTSERVER\3.0\ PBReader\Type\Registration Name: ReaderCount Type:REG_DWORD Data: 00000002 [Comment: Number of reader types] Key name: SOFTWARE\RW-470\PLOTBASE\ PLOTSERVER\3.0\ PBReader\Type\Registration\0 [Comment: settings for a reader type] Name: TypeExePath Type: REG_SZ Data: C:\RW-470\PLOTBASE\PROGRAM\ReSslru.
REGISTRY ENTRIES Name: TypeExePath Type: REG_SZ Data: C:\RW-470\PLOTBASE\PROGRAM\ReCfgru.exe [Comment: Reader path] Name: TypeName Type: REG_SZ Data: CFG - Interpreter [Comment: Reader name] Name: TypeReadyFilePossible Type:REG_DWORD Data: 00000001 [Comment: Setting, whether the Reader ReadyFiles are processed; 0:False, 1:True] Name: TypeWithDeaultSsl Type:REG_DWORD Data: 00000001 [Comment: Setting, whether a default SSL is used; do not change] Key name: SOFTWARE\RW-470\PLOTBASE\ SCANTOOL\3.
REGISTRY ENTRIES Data: C:\RW-470\PLOTBASE [Comment:Path for RW-470 SCANTOOL] Name: Path Type: REG_SZ Data: C:\RW-470\SCANTOOL\samples\ [Comment:last path used in the file selection] Name: LastFilterRead Type:REG_DWORD Data: 00000001 [Comment: saves the file extension that was last used, do not change] Name: ScannerDriver Type: REG_SZ Data: SeIfD1Ru.dll [Comment: File name of the scanner driver] Name: SSLDefaultFile Type: REG_SZ Data: Default.
REGISTRY ENTRIES Name: ScanBaseTempPath Type: REG_SZ Data: C:\DOCUME~1\ADMINI~1\LOCALS~1\Temp\ [Comment:Path of the temporary directory for RW-470 SCANTOOL] Name: EnableScanner Type:REG_DWORD Data: 00000001 [Comment: Switch the scan switch on, off; do not change] Name: ViewBrightness Type:REG_DWORD Data: 000000ffh [Comment: Save the brightness values in the file view] Name: HpglCfgFile Type: REG_SZ Data: C:\RW-470\PLOTBASE\HPGL.
REGISTRY ENTRIES Data: 00000000 [Comment: Add scan result to the drawing set; 0:Off, 1:On] Name: ScanToFilePath Type: REG_SZ Data: F:\\ [Comment: Path for ScantoFile files] Name: ScanToFileName Type: REG_SZ Data: SBAUTO [Comment:Name for ScanToFile file] Name: ScanToFileStartNo Type:REG_DWORD Data: 0000002f [Comment: Start number for ScanToFile file] Name: ScanToFileDigits Type:REG_DWORD Data: 00000004 [Comment: Digits for the consecutive numbering] Name: ScanToFileAutoStart Type:REG_DWORD Data: 00000000 [
REGISTRY ENTRIES [Comment: Activation of the “Scanner settings” window; 0:Off, 1:On] Name: StampActive Type:REG_DWORD Data: 00000000 [Comment: Activation of the stamp function; 0:Off, 1:On] Name: StampIFConfigName Type: REG_SZ Data: C:\RW-470\PLOTBASE\SCANTOOL [Comment:Path and basic name of the stamp configurations] Name: StampListConfigCnt Type:REG_DWORD Data: 00000000 [Comment: Number of stamps used; do not change] Name: ScannerSettings Type:REG_DWORD Data: 1287732,2013061208,1333112,1412768,1333120, 14
REGISTRY ENTRIES RW-470 63
REGISTRY ENTRIES Key name:SOFTWARE\RW-470\PLOTBASE\ SCANTOOL\3.0\ Set [Comment: settings for the character set] Name: SSLEntryViewing Type:REG_DWORD Data: 00000001 [Comment: Display of the entries selected in the file view; 0:Off, 1:On] Name: Ssl-Name Type: REG_SZ Data: SCANBASE.SSL [Comment: File name of the last drawing set saved] Key name:SOFTWARE\RW-470\PLOTBASE \ SCANTOOL\3.
REGISTRY ENTRIES [Comment: Only for internal management] Name: CALCOMP_CONFIG_FILE Type: REG_SZ Data: [Comment: This is the path for the Config File, where the basic settings for Calcomp are saved] Key name: SOFTWARE\RW470\PLOTBASE\PLOTSERVER\3.0\FORMATS\HPGL / HPGL2 Name: HP-FONTPATH Type: REG_SZ Data: [Comment: This is the path for the Ratio HPGL font files.
REGISTRY ENTRIES Name: HP-SETTINGS Type: REG_SZ Data: DATA-STRUCT [Comment: Only for internal management] Key name: SOFTWARE\RW-470\PLOTBASE\PLOTSERVER\3.0\FORMATS\ Intergraph Name: TileDX Type: REG DWORD Data: This is where the tile width is when saving this format, there are no facilities in the application for adjusting this value.
REGISTRY ENTRIES Key name: SOFTWARE\RW470\PLOTBASE\PLOTSERVER\3.0\FORMATS\Windows Metafile Name: Default Dpi Type: REG DWORD Data: This is where the default Dpi is. [Comment: Default value 400] Name: Default Lpi Type: REG DWORD Data: This is where the default Lpi is. [Comment: Default value 400] Name: Default DX Type: REG DWORD Data: This is where the default image width is with which the WMF should be loaded.
REGISTRY ENTRIES [Comment: Default “.;.
REGISTRY ENTRIES Data: ComboBox selection (0 - 4) Additional entries possible [Comment: Default 0] Name: HalfToneFrequency Type: REG DWORD Data: 1 - 999 [Comment: Grayscale manipulation] Name: HalfToneManual Type: REG DWORD Data: 0 Manual settings off 1 Manual settings on [Comment: Grayscale manipulation] Name: HalfToneMode Type: REG DWORD Data: 0 Background manipulation 1 General manipulation 2 Grayscale manipulation [Comment: Grayscale manipulation] Name: HalfToneSpotFunction Type: REG DWORD Data: ComboB
REGISTRY ENTRIES [Comment:] Name: PDFSettings Type: REG_SZ Data: DATA-STRUCT [Comment:] Name: UseHalftoning Type: REG DWORD Data: 0 Halftoning switched off 1 Halftoning switched on [Comment: Default 0] Name: UseScaling Type: REG DWORD Data: not used for PDF [Comment: Default 1] Key name: SOFTWARE\RW470\PLOTBASE\PLOTSERVER\3.0\FORMATS\RW-470PS / EPS Name: BasePath Type: REG_SZ Data: Basic path to the ghostscript files. [Comment: Should always be set to ’’.
REGISTRY ENTRIES Name: IncludePath Type: REG_SZ Data: Additional path for font files [Comment:] Name: Device Type: REG DWORD Data: 0 No color channel 1 Red 2 Green 3 Blue [Comment: Default 0, Color channel for BiColorMode] Name: EnableBiColor Type: REG DWORD Data: 0 BiColorMode switched on 1 BiColorMode switched off [Comment: Is set internally] Name: EnableLogging Type: REG DWORD Data: 0 for Logging switched off 1 for Logging switched on [Comment: Default 0] Name: HalfToneAccurateScreens Type: REG DWORD Da
REGISTRY ENTRIES [Comment: Default 0] Name: HalfToneFrequency Type: REG DWORD Data: 1 - 999 [Comment: Grayscale manipulation] Name: HalfToneManual Type: REG DWORD Data: 0 Manual settings off 1 Manual settings on [Comment: Grayscale manipulation] Name: HalfToneMode Type: REG DWORD Data: 0 Background manipulation 1 General manipulation 2 Grayscale manipulation [Comment: Grayscale manipulation] Name: HalfToneSpotFunction Type: REG DWORD Data: ComboBox selection (0 - 22) [Comment: Grayscale manipulation] Name:
REGISTRY ENTRIES Name: RW-470PSSettings Type: REG_SZ Data: DATA-STRUCT [Comment:] Name: UseHalftoning Type: REG DWORD Data: 0 Halftoning switched off 1 Halftoning switched on [Comment: Default 0] Name: UseScaling Type: REG DWORD Data: 0 Scaling switched off 1 Scaling switched on [Comment: Default 1, should usually be switched on. Only switch off in exceptional situations, if the PS file is not correctly scaled.
INDEX Index P C Calcomp Commands................. 44 Pens ........................... 45 CE-Certification ................ 8 CFG-File Commands................. 38 F File formats .................... 14 Font path ....................... 17 Front Side Bus .................. 5 H Hard drive........................ 5 Hardware......................... 5 HPGL/2-Commands....... 41 R Registry Entries ............... 47 S M Memory ........................... 6 Monitor ............................ 6 N Network ....