CORRECTIVE MAINTENANCE
122 RW-470 CLIENTS
Corrective maintenance
This chapter is primarily directed at the program administrator.
Several typical editing and system errors are listed. You are also
provided with suggested solutions.
Log-on not possible
Check the user name in the configuration. When logging-on, the
program is case-sensitive both for the User-ID as well as the
password – i.e. there is a difference between upper case and
lower case letters! If in doubt, ask your administrator.
After entering the ID and password, the Web
browser fails to react and waits...
... on a reply from the server. This is a sign that the program
cannot correctly access the license file. Check the correct instal-
lation of the dongle. A further reason for this lack of response
can be that the Apache Web Server, which is required for the
operation of the RW-470 PLOTCLIENT WEB, is running with in-
sufficient rights. Access to the license file is only possible, if the
Apache Web Server is registered as the system service or as a
service with user rights (of a user of the administrator group). A
more precise explanation is given in the chapter “installation“ of
the RW-470 PLOTBASE – manual.
No SSL-file is produced; locale files can not be
transmitted (upload pending)
Check the folder-configuration for the upload path. It is possible
that there are no write access rights for the directories given. For
access via UNC-paths, the Apache Web Server must run as a
service with user rights. More information about setting up the
Apache Web Server is given in chapter “installation“ of the RW-
470 PLOTBASE – manual. The last note refers to the specifica-
tion of local paths and mapped drives, which are accessed with
the aid of UNC notation.
No mail messages are sent
It is possible that the server name or the IP-address of the SMTP
server has not been set correctly. Check, if an e-mail address
has been given.