Service manual
28 March 2006 SCANNER
3-13
Replacement
Adjustment
Adjusting the Belt Contact Points for the Second Scanner
• ADF or platen cover
• Front cover (☛ 3.2.1)
• Operation panel (☛ 3.2.2)
• Rear cover (☛ 3.2.3)
• Top rear cover (☛ 3.2.4)
• Left upper cover (☛ 3.2.4)
• Exposure glass (☛ 3.4.1)
1. Disconnect the platen cover sensor connector [A].
2. Scale bracket [B] ( x 2)
NOTE: 1) Take off the scale bracket, otherwise the screws [D] cannot be
loosened.
2) Take off the bracket [C] in order to take off the scale bracket.
C267R081.WMF
[A]
[B]
[C]