Service manual
T
echnical
B
ulletin
PAGE: 2/7
Model:
Bellini-C1/C2 Date: 31-Oct-03 No.: RB070029
SOLUTION
Please perform the following if the symptom still occurs, even after
performing the above checks.
1. Toner scattering in the rear of the machine
a) Attach the new seal (B0703617) to the drum cleaning unit pipe as shown below, in
order to seal the connection between the drum cleaning unit and toner recycling case.
IMPORTANT:
Check the following items before performing the solution below.
1. Check the toner filter [A] and drum filter [B], and clean or replace them as necessary.
Note:
The toner filter should be replaced every 300k (Bellini-C1) or 350k (Bellini-C2).
The above cleaning/replacements are also effective in maintaining proper machine internal
temperature, which is key in minimizing scattering since slight rises in temperature can cause
scattering to occur more easily.
2. If toner scattering still occurs, clean the toner transport path.
Seal: B0703617
(A)
(
B
)