Auto Process Control: Bellini-C2
Note: The following explanation applies to the B-C2 and B-C1a/b/c/d, except for the values that differ from model to model mentioned in
Section 4.
!
!!
! Execution Conditions
There are three separate cases in which the machine performs Auto Process Control:
1. When it is executed manually from SP2962 (Auto Process Control Execution).
2. When SP3901-001 (Auto Process Control Setting) has been set to ON, and the fusing
temperature is detected at 100
o
C or less at power up.
Note:
If the fusing temperature is higher than 100
o
C at this time, the previous auto process
control data is used.
3. When all of the following conditions have been met:
a) SP2966 (Periodical Auto Process Control) has been set to ON
b) 24hrs has passed since the last time Auto Process Control was performed
c) The main power has been ON during this 24hr period
* Auto Process Control is then performed at the end of the job following the 24hr mark.