Service manual
T
echnical
B
ulletin
PAGE: 1/4
Model:
Bellini-C2
Date:
7-Apr-03
No.:
RB070001
Subject:
SC672 etc
Prepared by:
M. Matsuda
From:
2nd Tech Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
The Bellini-C2 firmware has been modified to solve the following:
SYMPTOM
1. SC672 (controller start-up error)
2. NetWare printing error
The machine will not accept print jobs after a certain amount have been sent via NetWare.
3. Words missing (French/Spanish)
Some words are not displayed in French (missing from wording lists).
4. Printing speed with Standard TCP/IP Port is too slow
CAUSE
The software was not designed to prevent the above.
SOLUTION
The following firmware has been modified and applied from March 5
th
‘03 production.
1. SC672 (controller start-up error).
Solution:
Controller, LCDC and Bios firmware modifications.
Note:
There are a total of 9 separate causes that can trigger SC672. To cover all
possible causes, it is necessary to modify all the firmware listed above.
2. NetWare printing error
Solution:
NIC firmware modification.
3. Words missing (French/Spanish):
Solution:
LCDC firmware modification.
4. Printing speed with Standard TCP/IP Port is too slow
Solution:
NIC firmware modification.