2. Firmware Modification
Due to the counter modification, SP5-849 has also been changed as follows for products
that have this SP mode (listed below).
SP mode name: Specification:
Current Counter Clear
Day
•
When the electrical counter is changed
from a
negative value to 0
, the machine recognizes this
as the counter clear day and stores this date in the
NVRAM.
New Installation Date
• When the electrical counter reaches a value of
20, the machine recognizes this as the installation
date and stores this date in the NVRAM.
NOTE: The following products have SP5-849. The new firmware for these products has
not yet been released. However the release notes for each will clearly mention the
new firmware version.
New products: Bellini-C2, Adonis C3
Current products: Martini C1, Model-U C1
3. Schedule for the Counter Modification
The following is the current schedule for when the counter modification will be applied.
Please note that there are some models to which the change will not be applied (marked
as “---“), due to production schedules, production lot quantities and sales figures.
NOTE: The actual cut-in months that have been confirmed appear in the “Cut-in
production month” column below. This RTB will be reissued when these dates
have been confirmed for the remaining products.
(1) New products
Product Name Product
Code
Target cut-in
production month
Cut-in production month
Bellini C2 B070 2003.03 April ’03 production
Adonis C3 B079/82 2003.03 First mass production lot
Model J-P2 G080 2003.03 March ’03 production
Model J-P2 CF G367 2003.03 March ’03 production
Model AR- P1 G081/92 2003.03 March ’03 production
Model K-C1a B120 2003.03 March ’03 production