Service manual

Technical Bulletin PAGE: 1/2
Model: Bellini-C2 Date: 28-Dec-06 No.: RB070065
Subject: Patch Release for EB-105EX V.1.2 (1-MMWR9) Prepared by: Chisato Tsuji
From: 2nd Tech Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
This RTB is the release note for Patch File 1-MMWR9 for EB-105EX printer controller
System V1.2.
Patch File Issue(s)
1-MMWR9 This 1-MMWR9.ps patch will fix the following problems:
l Printing with A4 Full bleed + A3/Z-Fold/Staple causes the job to
cancel unexpectedly.
l While printing a mixed media job on full bleed A3 and A4-LEF with
Z-folding in Acrobat, the EB-105EX prompts for A4-SEF
incorrectly.
Note:
l This patch is only for EB-105EX System Version 1.2.
Prerequisite(s):
l Before this patch is applied, the following patches should already be applied on the
system in the following order.
1-HASH8.ps (If the FPGA revision is already 20, then this patch is not needed)
1-LV4GA.ps
1-N69ZD.ps
1-N522T.ps
1-OT69U.ps
Patch Update Procedure
1. Print out the configuration page and check that the prerequisite patches are already
installed on the system software v.1.2.
(If not, install the prerequisite patches first.)
2. Extract G3538989.exe until you get the 1-MMWR9.ps file.
3. Use the Fiery Downloader to download the patch file (1-MMWR9.ps) to the Direct
queue.
4. Wait at least 60 seconds.
Note: This is very important.
5. Reboot the EB-105EX.