Service manual

Technical Bulletin PAGE: 1/1
Model: Bellini-C2 Date: 04-Aug-06 No.: RB070020a
RTB Reissue
The items in bold italics have been added.
Subject: Firmware History (Bellini-C2 Printer) Prepared by: S.Ishizu
From: Technical Services sec. Service Planning Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
This is to inform you of the firmware history for the Bellini-C2 Printer.
B5806415 Version C.SUM Production
- V1.00 - 1st Mass Prod.
B5806515 V1.13 2D42 April Prod 03
A V1.20 BA55 July Prod 03
B5806516 V2.07 AE88 April Prod 04
B5806516A V2.09 Jul Prod 06
Symptom Corrected
Suffix
1. 0 counter
2. SMTP Authentication
Note: For details, refer RTB RB070003
B5806515
1. Only the first duplex command is interpreted correctly when printing PCL files containing
simplex, duplex (short) and duplex (long) commands (GFPR #RC03020001).
2. Downloaded PCL barcode fonts are not printed correctly on the PCL font list (GFPR
#RC03010004).
3. Merged PCL job does not print (TechMail #TS030100).
The machine prints out 99 copies of a 1-page document set for 300 copies when the driver is
at standard settings (GFPR #RC03050014, RE03050021).
A
IMPORTANT NOTE: Refer to RTB RB070039 at the firmware installation
1. Firmware modified for upgrade to the Bellini-C2e (enhanced version) by supporting use
with the Z-fold unit and Victoria-D (B706).
B5806516
1. The "Clear/Stop" button can cancel print jobs like the "Job Reset"button.
2. Printer settings can be configured from either the operation panel or WIM.
Configuration of printer settings via WIM requires both Printer firmware Ver 2.09
(Part#B1805958C) or later and Websys firmware Ver 2.05 (Part#B0705777A) or
later.
3. The page counters of some jobs may be incorrect in the Job History section of
WIM. This only affects duplex jobs that have 9 or more pages processed in the
MFP at one time. The problem affects any utilities (not only WIM) that queries the
MFP for the page counter of a job via MIB or the PJL USTATUS PAGE command.
4. Acrobat jobs sent to the Document server via the RPCS driver with a "Job Load
Distribution" setting of "Automatic" or "Shift load to printer", might have vertical
blank stripes of data missing from the image. Only Adobe Acrobat version 5.x is
affected.
B5806516A