Service manual

T
echnical
B
ulletin
PAGE: 1/1
Model:
Bellini-C2 Date: 21-Sep-04 No.: RB070047
Subject: ROM History for SR841 Prepared by: M. Matsuda
From: 2nd Tech Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
This is to inform you of the ROM history for the SR841 (VICTORIA-D).
ROM No Main PCB No Version C.SUM Production
B7065105 B7065130 V1.10 3208 1st Mass Prod.
B7065106 B7065131 V1.11 7899 *See below 4
B7065106
1.Symptom:
The Bellini-C2e does not detect the Plockmatic (SR90), which is connected via the Victoria-D.
2.Cause:
Some signal-control codes for communication with the Plockmatic were missing from the Victoria-D
EPROM firmware.
3.Solution:
The firmware was modified (coding error corrected).
4. *Serial numbers for Victoria-D with P/N B7065105
Serial Number Qty. Model Serial Number Qty.
Model
From To
From To
5C30440001 5C30440012 12 K3140300001 K3140300004 4
5C30440014 5C30440040 27 K3140300005 K3140300272 268
5C30540001 5C30540049 49 K3140400001 K3140400354 354
B706-26
Total 88 K3140500158 K3140500161 4
K3140500168 - 1
K3140500180 - 1
K3140500182 - 1
K3140500186 - 1
K3140500188 - 1
K3140500191 - 1
K3140500193 K3140500230 38
B706-17
Total 674