Service manual
T
echnical
B
ulletin
PAGE: 2/2
Reissued: 16-Sep-04
Model:
Bellini-C2
Date:
21-Jul-04
No.:
RB070046a
LCDC Recovery Procedure
IMPORTANT: If you are updating the machine from a Bellini-C2 to a Bellini-C2e
(enhanced model), this recovery procedure will not work. In this case, replace the
LCDC board.
Reason: The recovery program is overwritten only when you update from the B-
C2 to the B-C2e.
See RTB RB070039 for details about the B-C2e firmware.
1. Insert an SD card which contains the LCDC firmware.
2. Turn the main power ON. The operation panel will display the following message:
Warning
Install failure of operation panel program
Turn machine off
Set SD card of operation panel and turn on
3. Make sure to
wait for the update to begin
. This will take about one minute.
As mentioned at the top of this RTB:
Important:
A common cause of firmware update failures is when the main power is turned off
during the update. Please make sure to wait until the Main Power ON Key flashes at
intervals of about 3 seconds, and then turn the main power off (see Service Manual
section 5.10.4).