Service manual
T
echnical
B
ulletin
PAGE: 7/15
Model:
Bellini-C2 Date: 4-Feb-04 No.: RB070038
2) LD Units:
SP2115-007 has been newly added to increase the accuracy of the LD beam pitch. To
activate this SP mode, it is necessary to manually input the value shown at the bottom
right of the label (see below) when replacing the LD unit.
New decal on the LD unit
3) Fusing Temperature:
The adjustable range for the fusing temperature has been changed as follows.
SP Old Function/[Setting] New Function/[Setting]
SP1105-001
B070: [168~178/
168
/ 1 deg]
B071: [168~178 /
173
/ 1 deg]
B070: [
120
~178/
168
/ 1 deg]
B071: [
120
~178 /
173
/ 1 deg]
SP1105-002
B070: [148~158 /
148
/ 1 deg]
B071: [148~158 /
153
/ 1 deg]
B070: [
100
~158 /
148
/ 1 deg]
B071: [
100
~158 /
153
/ 1 deg]
<LD Unit Lot No.>
SP2115 001/SP2115 002/SP2115 003
PS2115 004/SP2115 005/SP2115 006/SP2115 007
B070R978.WMF
New value for SP2115-007
manual input