User's Manual
Installation Guide For
Savi-EJ Brooks Re-Usable eSeal ST-661
Page 2 of 3 pages ELECTRONIC COPY
NOT CONTROLLED IF PRINTED
Date Prepared Revision Revision Date Revision Approval
Feb 24, 2006
1.0
Feb 24, 2006 K. Merritt
Savi-EJB Installation Guide - ST-661.doc
Tag Attachment
Tag Attachment Tag Attachment
Tag Attachment
Do not insert the bolt
through the body of the tag
housing prior to inserting it
through the security hasp. Once
the internal bushing is joined to
the bolt, it cannot be removed
without destroying the housing.
The Savi-EJ Brooks ST-661 contains an integrated locking bolt assembly.
1. Place the bolt through the lock holes of the closed security hasp.
• Always orient the tag with the main tag body below the container hasp.
2. Snap the bolt into the seal housing far enough to hear an audible ‘click’, locking the bolt into place,
where the bolt is pushed in all the way. To make sure the bolt is secure, pull on the seal case housing
gently to make sure the bolt is secure. The bolt is now secured via the unit’s internal bushing.
Tag Operation
Tag OperationTag Operation
Tag Operation
• After installation you may communicate with the device and monitor events using the
appropriate commands from a Savi Mobile Readers SMR-650 or Fixed Readers SR-650 and
SP-652.
• Once the tag is electronically locked (sealed), if the bolt is cut or removed, a tamper event will
occur.