User's Manual

&RQILJXULQJWKH8+)5HDGHU0RGXOHLQ6PDUW&KDLQ6LWH0DQDJHU
6DYL6LJQSRVW63;6HULHV,QVWDOODWLRQ*XLGH 
 Set the low frequency power level.
For Savi Signpost SP-65X Series models SP-650-211, SP-651-211, and
SP-652-211 with the large air core antennas, you use the maximum
setting of 724, in compliance with international emissions standards. For
all other Savi Signpost SP-65X Series models, you use the maximum
setting of 1023.
 Set the Tx mode to normal mode.
 Verify the status of the signpost and that all signposts are compatible
with the system.
&RQILJXULQJWKH8+)5HDGHU0RGXOH
LQ6PDUW&KDLQ6LWH0DQDJHU
Savi Signpost SP-65X Series models SP-652-011, SP-652-111, SP-652-211,
SP-652-311, SP-652-101, and SP-652-201 must be configured over the
Ethernet connection and connected to SmartChain Site Manager.
The UHF reader module in all of these signpost models:
Allows you to send data from tags it receives once the host IP address is
set and the time is synchronized
Responds to tags that are triggered by the low frequency signpost signal
after a UDAP command is sent
6HWWLQJWKH+RVW,3$GGUHVVDQG6\QFKURQL]LQJ
7LPH
You can use the Network Manager to configure some properties of UDAP
devices that are also signposts embedded with the UHF reader module. You
can set the host and local IP addresses and other network information and
time synchronization parameters. You can also send some simple
commands such as
UHVHW and FOHDU. To send more complex commands, use
the Send Commands dialog. See “Sending UDAP Commands” on page 28.
To set the host IP address and synchronize time:
 On the desktop, click the Site Manager Console icon.
 Click the Network Management button.